User name Yi Qiang
Log entry time 23:14:53 on May 06, 2009
Entry number 271337
Followups:
keyword=R-HRS is running with Unbuffered Mode and Neutron Detector ON
Because that the busy signal from ROC8 still gives us problem, Vince and
Bo unplugged it. So it leaves us two options, run R-HRS DAQ with
unbuffered mode and Neutron Detector On or run R-HRS DAQ with buffered
mode and ND OFF. We first tried to run unbuffered mode with ND ON. With
10 uA, the online DATAMON shows a 16-17% dead time, and the offline
NormAna analysis shows a 14 % dead time. Compared to the 5% dead time
with buffered mode, Vince, Bo and I all think it's not bad so we will ask
the shift crew to keep running production like this. We will try to find
another opportunity to try to fix this problem.
A copy of this log entry has been emailed to: tdaver@wm.edu, jpchen, jiang, doug, vasulk, zhaobo