keyword=Spectrometer Motion Problems (Late Entry)
Today prior to the pass change, Doug and I went to the hall to move the
left and right HRS to 17 degrees. First we could not get the left HRS
bogie controls window to open. After rebooting and power cycling the VME
crate, we could get the window to open, but the GUI was completely black
and an error message would pop up. We noticed that the VME bus board
2311 had it's 'FAIL' lit up.
We consulted with Ed Folts and Scot Spiegel about the problem. Scot
said that we needed to also power cycle the bogies themselves. After
Scot did this, the rear bogie relay was no longer responsive and needs
to be replaced. Doug decided that he was fine with leaving the left HRS
at 12.5 degrees. So the repair will wait until Monday.
After we moved the right HRS to 17 degrees, Doug and I removed the 2311
VME bus board from the right HRS VME crate. Unfortunately when we
replaced the board, the 'FAIL' LED was also illuminated. Hence the
right HRS is currently unmovable from 17 degrees.