16:00 MCC started to put beam back to Hall A
~17:00 asked MCC to do harp scan for A & B
17:35 Harp scan done
17:40 raster study run:3513/22380, about 4 mm by 4.5 mm (7 by 5 MCC))
17:50 raster size study with 3He target run 3514/22381 (2mm by 2mm)
3 by 3 (MCC)
Target polarization measured 64.5%
run 3515/22382 MCC 10 by 8 (6 mm by 6mm)
18:25 started 3He production run 3517/22384 new Happex run 31521
wrong prescale for left HRS.
19:24 started 3He production run 3518/22385 wrong prescale for left HRS
19:32 started 3He production run 3519/22386 T3 need at least 1kHz rate
20:08 started 3520/22387 Right CODA crashed just before we requested escorted acccess for the Compton detector
21:08 MCC call for beam ready; starting beam recovery @ BeO target
21:20 Raster check OK on carbons. Going to He3 Cell
21:25 NMR -> 54% Pol.
21:26 Raster check on He3 is OK. Ramp current to 10uA. Start production
21:27 Start production pair 3524/32391. BPM is unstable
22:00 started production run 3525/22392
22"10 MCC called and needs to take beam for half an hour for investigating some vacuum problem.
22:27 beam back; production run 3526/22393
23:50 LHRS Q1; RHRS Q1,D,Q3 quenched due to low level (~0%) of Helium. Stop beam/production runs