    User name Jin Huang

    Log entry time 17:06:31 on June 23, 2009

    Entry number 281935

    Followups:

    keyword=Target NIM Crate Dissembled

    Target NIM Crate in counting house middle room are dissembled. There were

    One PS757, which was borrowed from Bigbite DAQ, was returned to Vince.

    Two PS706, which was marked as "GEN", were stored in Counting House Front room back up module storage shelf.

    Two PS756, which were borrowed from Duke Univ, were returned to Yi Qiang. There were a large collection of LEMO cables (2ns, 4ns, 6ns, 8ns), which are now stored in counting house middle room cable racks.

    special Note For Parity People

    In counting house middle room, there is a parity DAQ crate. Part of its cables are running through a level transistor on Target NIM Crate. This crate could be removed before next experiment. Therefore, please moved this cable to other permanent modules. For now, I am going to keep this transistor running, until removing of target crate from counting house is necessary.