NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 16:06:05 on August 17, 2009
Entry number 284706
keyword=Start_Parity_Run_44167__CODA_Config=_Run_type=other,beam_energy=3.179,beam_polarization=186,beam_raster=on,comment_text=LED tests, LED baseline power unplugged,leftarm_p=3.1234,leftarm_theta=6,parity_feedback=off,parity_ihwp=in,rightarm_p=3.1126,rightarm_theta=6,target_fanspeed=90Hz,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 44167 at Mon Aug 17 16:06:00 EDT 2009
CODA Configuration:
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 0
Wien angle : 17.496
Wien BDL : 398.03
Wien field : 11.563
Laser attenuation Hall A : 200
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.8
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.64
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.554
Gun2: PC (PITA) NEG : 6.238
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00733
Pockels Cell Voltage NEG : 1.83394
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Laser power : Pwr725mW
Calculated power in cavity : 0.152272
Photodiode on table : 703.888
Laser X position on QPD 1 : 131.771
Laser Y position on QPD 1 : 967.023
Laser X position on QPD 2 : -23.9408
Laser Y position on QPD 2 : -1071.83
QPD 1 sum : -0.694623
QPD 2 sum : -0.559116
Position set point for adjustable mirror 1 (either x or y) : -885[c]
Position set point for adjustable mirror 2 (either x or y) : -3880[c]
Laser crystal minimum temperature (epics constant used for calculating temperature offsets) : 35.8
Laser temperature set point : +48.1933
Polarisation set point of laser in cavity : LEFT
Signal reflected from cavity input mirror : 0.481597
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 2.36404
Calculated polarisation in cavity : 18.7989
Signal of one polarisation state after Wollaston prism : 0.00488619
Signal of other polarisation state after Wollaston prism : 0.00886212
Step size for rotating half wave plate scan : 11162
Slow ramping of laser temperature when not locked (1 = on) : ON
Extent of laser temperature slow ramp (degrees C) : 0.2
Speed of laser temperature slow ramp up : 150
Speed of laser temperature slow ramp down : 150
Parity DAQ Feedback Control(1=on) : 0
Left Arm arm angle : -0.179
Right Arm arm angle : 0.197
Left Arm Q1 power supply current : 100.671
Left Arm Q1 momentum : 0.133572
Left Arm Q1 gauss meter : -0.00824
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 96.8244
Left Arm Q2 momentum : 0.222204
Left Arm Q2 gauss meter : 0.05068
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 98.5422
Left Arm D1 momentum : 0.298444
Left Arm D1 NMR : 0.286566
Left Arm Q3 power supply current : 101.135
Left Arm Q3 momentum : 0.255304
Left Arm Q3 gauss meter : -0.050266
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 100.404
Right Arm Q1 momentum : 0.133499
Right Arm Q1 gauss meter : -0.0025268
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 99.6593
Right Arm Q2 momentum : 0.228145
Right Arm Q2 gauss meter : 0.05159
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.118887
Right Arm D1 momentum : 0.00616739
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : 99.7272
Right Arm Q3 momentum : 0.248461
Right Arm Q3 gauss meter : 0.04409
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 0.683594
Left Arm Bottom VDC Current : -1.41602
Right Arm Top VDC Current : -14.4043
Right Arm Bottom VDC Current : -2.29492
Left Arm Top VDC voltage : 4.00146
Left Arm Bottom VDC voltage : 4.00049
Right Arm Top VDC voltage : 4.00195
Right Arm Bottom VDC voltage : 4
Average current of the two cavities : 0.0256526
Current on Unser monitor : -6.22553
Current on Upstream bcm : 0.0385779
Current on Downstream bcm : 0.0126942
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 1.3438
Tiefenbach Hall A energy : 6063.87
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 5871.82
MBSY3c Hall C Beam energy : 5884.04
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 1.46532e+06
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.393994
HacL_HPE1313A:0_Ch58 : -0.207031
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : 0.0380859
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.362891
HacR_HPE1313A:0_Ch58 : -0.634277
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.962891
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out