    User name R Michaels

    Log entry time 15:07:14 on August 23, 2009

    Entry number 285471

    This entry is a followup to: 285468

    keyword=

    fEvtHdr.fEvtType is determined by the trigger supervisor. The first trigger N=1,2,3 (etc)
    which arrives in time determines evtype=1,2,3 but if they overlap within the window (ca
    10 nsec) CODA calls it "evtype=5". Meanwhile D.evtypebits is determined by a TDC which
    looks at triggers AFTER prescaling. Cut on a time window to determine if the bit is there.
    Whether this is correctly plugged in, where it is plugged in, and what the TDC cuts need to
    be should be checked before running if you care about the info. I doubt that it was checked,
    and considering the big upheaval from Bigbite it should probably be checked.
    The general ideas of CODA event type, etc, are documented in great detail on the DAQ page.