Log entry time 20:35:03 on September 15, 2009
Entry number 289790
Followups:
keyword=Injector studies
Took data with Pockels cell off to quantify false asymmetries from
electronics pickup.
Did a Hall C IA scan (with Pockels cell off) to determine the slope for
doing Hall C beam charge feedback. The slopes are +250 ppm/V for both
half wave plate states. [12350 and 12351]
A rotating half wave plate scan was done and it was decided to stay at
the current RWP setting of 1200 (30 degrees.) [12352 and 12353]
Did a Hall A PITA scan and got slopes of -5.1 ppm/V and +4.9 ppm/V for
HWP IN and OUT respectively. [12354 and 12356]
Yves tried some new quad settings that produced bigger position
differences with broader distributions. [12358]
Measured the Hall C charge asymmetry (PC on) and found it small ~8 ppm.
Did this again with CIA=7 and found Hall CA went up to 460 ppm. [12358
and 12359]
Measured the Hall C PITA slope for IHWP OUT and got -4.6 ppm/V (which is
opposite to our PITA slope for ihwp out) [12361]