NEXT
Make New Entry,
Make Followup Entry
User name silwal
Log entry time 12:16:31 on September23,2009
Entry number 291151
keyword=modified .db files to reflect datamap changes in bpm8/14, and scanclean/scandata flags
Changes made:
1. modified bpm10s to bpm14s (what we thought were bpm10s were actually bpm14s)
2. switched bpm8s from scaler0 to adc7, bpm8 signals switched to adc7 starting
about run # 12579
3. added scanclean flags and modified scandata flags so that counting house,
right arm, left arm, and the Happex injector all have their own
scanclean/scandata flags.
New (counting house):
datamap bpm bpm8 adc 7 0 bpm8xp bpm8xm bpm8yp bpm8ym
datamap bpm bpm14 adc 11 0 bpm14xp bpm14xm bpm14yp bpm14ym
---
Old (counting house):
datamap bpm bpm8 scaler 0 20 bpm8yp bpm8ym
datamap bpm bpm10 adc 11 0 bpm10xp bpm10xm bpm10yp bpm10ym
New (right arm):
datamap daqflag daqflag6 daqflag 1 0 6 26 scanclean3 scandata7 scandata8
---
Old (right arm):
datamap daqflag daqflag4 daqflag 1 0 6 26 scandata3 scandata4
New (left arm):
datamap daqflag daqflag5 daqflag 1 0 5 25 scanclean2 scandata5 scandata6
---
Old (left arm): no scanclean/scandata flags previously
New (Happex Injector):
datamap daqflag daqflag4 daqflag 1 0 5 24 scanclean1 scandata3 scandata4
---
Old (Happex Injector):
datamap daqflag daqflag9 daqflag 1 0 5 24 scandata9 scandata10 scandata11