User name apar
Log entry time 00:46:13 on September 24, 2009
Entry number 291325
keyword=Start_Parity_Run_12621__CODA_Config=happex3_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=10uA,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=72Hz,target_type=25cm LH2
Beginning-of-Parity-run EPICS data for Run Number 12621 at Thu Sep 24 00:46:06 EDT 2009
CODA Configuration: happex3
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 19664
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 78
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.353
Gun2: PC (PITA) NEG : 6.347
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.99756
Pockels Cell Voltage NEG : 1.84371
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr757mW
Calculated power in cavity : 954.43
Photodiode on table : 413.759
Laser X position on QPD 1 : 144.401
Laser Y position on QPD 1 : 484.722
Laser X position on QPD 2 : -21.3854
Laser Y position on QPD 2 : -588.794
QPD 1 sum : -1.96911
QPD 2 sum : -1.37704
Position set point for adjustable
mirror 1 (either x or y) : -320[c]
Position set point for adjustable
mirror 2 (either x or y) : 1780[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1518
Polarisation in cavity : RIGHT
Reflection photodiode : 0.39248
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.159311
Fast locking signal sent to laser : 8.91961
Calculated polarisation in cavity : 97.938
Photodiode 1 after Wollaston prism : 74.656
Photodiode 2 after Wollaston prism : 0.777738
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot2 Ch9 : -1589.4
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : -0.179
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.08
Left Arm Q1 momentum : 3.14101
Left Arm Q1 gauss meter : -0.19939
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.77
Left Arm Q2 momentum : 3.14159
Left Arm Q2 gauss meter : 0.7106
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1103.83
Left Arm D1 momentum : 3.14165
Left Arm D1 NMR : 1.1634
Left Arm Q3 power supply current : 1250.86
Left Arm Q3 momentum : 3.14193
Left Arm Q3 gauss meter : -0.63107
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.17
Right Arm Q1 momentum : 3.14139
Right Arm Q1 gauss meter : -0.05867
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1351.89
Right Arm Q2 momentum : 3.14124
Right Arm Q2 gauss meter : 0.7062
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.81
Right Arm D1 momentum : 3.14153
Right Arm D1 NMR : 1.16578
Right Arm Q3 power supply current : 1250
Right Arm Q3 momentum : 3.14143
Right Arm Q3 gauss meter : 0.5593
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.46484
Right Arm Top VDC Current : -1.66016
Right Arm Bottom VDC Current : -1.46484
Left Arm Top VDC voltage : 0.0175781
Left Arm Bottom VDC voltage : 0.0185547
Right Arm Top VDC voltage : -0.0117188
Right Arm Bottom VDC voltage : -0.00878906
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 5.05626
Current on Unser monitor : -2.06675
Current on Upstream bcm : 4.92101
Current on Downstream bcm : 5.19151
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 17.8944
Tiefenbach Hall A energy : 3483.01
Tiefenbach Hall C energy : 2344.1
Delta(E)/E width (MV_AI_DXWID) : 3.81572
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.515498
IPM1C12.YPOS : 0.147848
IPM1H04A.XPOS : -0.242642
IPM1H04A.YPOS : 1.49198
IPM1H04B.XPOS : -0.717501
IPM1H04B.YPOS : 2.23661
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.517024
Survey Y offset bpm12 : 0.152676
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619678
HacL_HPE1313A:0_Ch58 : -0.205078
HacL_HPE1313A:0_Ch55 : 22.9492
HacL_HPE1313A:0_Ch54 : 0.019043
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.0237793
HacR_HPE1313A:0_Ch58 : -0.627441
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.966309
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 72.5
Encoder position : 17740750
temperature loop 3-1 : 18.98
temperature loop 3-2 : 18.99
temperature loop 3-3 : 0.9
pressure fill target H2 : 27.8782
pressure fill bottle H2 : 28.2979
pressure ballast H2 : 28.0308
pressure exhaust H2 : 27.8965
cryogen input temp : 13.6
crogen return flow : 24.543
JT valve setting : 52.6367
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 12621 -d '2009-09-24 00:44:50' -t 17740750 -s IN