    User name apar

    Log entry time 09:14:28 on September 24, 2009

    Entry number 291377

    keyword=Start_Parity_Run_12633__CODA_Config=happex3_Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=100uA,FBB off,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=72Hz,target_type=25cm LH2
    Beginning-of-Parity-run EPICS data for Run Number 12633 at Thu Sep 24 09:14:21 EDT 2009
    CODA Configuration: happex3
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 19667
    -----------------------------------------
    Wien angle                               : 17.1968
    Wien BDL                                 : 395.55
    Wien field                               : 11.363
    Laser attenuation Hall A                 : 83
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.348
    Gun2: PC (PITA) NEG                      : 6.352
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 1.99512
    Pockels Cell Voltage NEG                 : 1.84127
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Quartet
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr746mW
    Calculated power in cavity               : 885.313
    Photodiode on table                      : 405.035
    Laser X position on QPD 1                : 151.459
    Laser Y position on QPD 1                : 479.37
    Laser X position on QPD 2                : -23.4607
    Laser Y position on QPD 2                : -584.76
    QPD 1 sum                                : -1.97034
    QPD 2 sum                                : -1.34652
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -320[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : 1780[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.1427
    Polarisation in cavity                   : LEFT
    Reflection photodiode                    : 0.336324
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 0.503571
    Fast locking signal sent to laser        : 5.6638
    Calculated polarisation in cavity        : 98.0719
    Photodiode 1 after Wollaston prism       : 0.674538
    Photodiode 2 after Wollaston prism       : 69.2957
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 1
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot2 Ch9     : -1589.4
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : -0.179
    Right Arm arm angle                      : 14.001
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 2363.13
    Left Arm Q1 momentum                     : 3.14108
    Left Arm Q1 gauss meter                  : -0.1994
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1352.79
    Left Arm Q2 momentum                     : 3.14164
    Left Arm Q2 gauss meter                  : 0.7106
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1103.83
    Left Arm D1 momentum                     : 3.14166
    Left Arm D1 NMR                          : 1.1634
    Left Arm Q3 power supply current         : 1250.88
    Left Arm Q3 momentum                     : 3.14199
    Left Arm Q3 gauss meter                  : -0.63111
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 2362.12
    Right Arm Q1 momentum                    : 3.14139
    Right Arm Q1 gauss meter                 : -0.05865
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1351.91
    Right Arm Q2 momentum                    : 3.14129
    Right Arm Q2 gauss meter                 : 0.7062
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 1135.85
    Right Arm D1 momentum                    : 3.14155
    Right Arm D1 NMR                         : 1.16579
    Right Arm Q3 power supply current        : 1250.02
    Right Arm Q3 momentum                    : 3.14148
    Right Arm Q3 gauss meter                 : 0.5593
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : 1.41602
    Left Arm Bottom VDC Current              : 1.41602
    Right Arm Top VDC Current                : -1.66016
    Right Arm Bottom VDC Current             : -1.36719
    Left Arm Top VDC voltage                 : 0.0180664
    Left Arm Bottom VDC voltage              : 0.0185547
    Right Arm Top VDC voltage                : -0.0117188
    Right Arm Bottom VDC voltage             : -0.00878906
    -----------------------------------------
    Beam Info
    -----------------------------------------
    Average current of the two cavities      : 5.59542
    Current on Unser monitor                 : -1.74775
    Current on Upstream bcm                  : 5.47079
    Current on Downstream bcm                : 5.72005
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 13.0067
    Tiefenbach Hall A energy                 : 3483.12
    Tiefenbach Hall C energy                 : 2344.14
    Delta(E)/E width (MV_AI_DXWID)           : 3.89733
    MBSY1c Hall A Beam energy                : 3489.72
    MBSY3c Hall C Beam energy                : 2349.75
    MBSY1c magnet current (amp)              : 145.346
    MBSY1c Bdl                               : 870864
    IPM1C12.XPOS                             : 0.327013
    IPM1C12.YPOS                             : 0.233689
    IPM1H04A.XPOS                            : -0.309942
    IPM1H04A.YPOS                            : 1.0859
    IPM1H04B.XPOS                            : -0.789833
    IPM1H04B.YPOS                            : 1.94727
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0.327013
    Survey Y offset bpm12                     : 0.233689
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.619678
    HacL_HPE1313A:0_Ch58                     : -0.20459
    HacL_HPE1313A:0_Ch55                     : 22.8516
    HacL_HPE1313A:0_Ch54                     : 0.019043
    Left Arm Angle Floor Angle               : 0
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : -0.179
    Right Arm Collimator                     : 0.0232422
    HacR_HPE1313A:0_Ch58                     : -0.626953
    HacR_HPE1313A:0_Ch55                     : 22.168
    HacR_HPE1313A:0_Ch54                     : -0.96582
    Right Arm Angle Floor Angle              : 14
    Right Arm Angle Vernier                  : -34
    Right Arm Scattering Angle               : 14.001
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    fan frequency loop 3                     : 72
    Encoder position                         : 17740750
    temperature loop 3-1                      : 19.02
    temperature loop 3-2                      : 19.02
    temperature loop 3-3                      : 0.9
    pressure fill target H2                   : 28.1712
    pressure fill bottle H2                   : 28.4596
    pressure ballast H2                       : 28.5328
    pressure exhaust H2                       : 28.1163
    cryogen input temp                        : 13.7
    crogen return flow                        : 24.6622
     JT valve setting                         : 53.0762
    -----------------------------------------
    #
    # command to log run in database (should already have been done)\n
    /adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 12633 -d '2009-09-24 09:14:18' -t 17740750 -s IN