Log entry time 09:14:28 on September 24, 2009
Entry number 291377
keyword=Start_Parity_Run_12633__CODA_Config=happex3_Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=100uA,FBB off,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=72Hz,target_type=25cm LH2
Beginning-of-Parity-run EPICS data for Run Number 12633 at Thu Sep 24 09:14:21 EDT 2009
CODA Configuration: happex3
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 19667
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 83
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.348
Gun2: PC (PITA) NEG : 6.352
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.99512
Pockels Cell Voltage NEG : 1.84127
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 885.313
Photodiode on table : 405.035
Laser X position on QPD 1 : 151.459
Laser Y position on QPD 1 : 479.37
Laser X position on QPD 2 : -23.4607
Laser Y position on QPD 2 : -584.76
QPD 1 sum : -1.97034
QPD 2 sum : -1.34652
Position set point for adjustable
mirror 1 (either x or y) : -320[c]
Position set point for adjustable
mirror 2 (either x or y) : 1780[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1427
Polarisation in cavity : LEFT
Reflection photodiode : 0.336324
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.503571
Fast locking signal sent to laser : 5.6638
Calculated polarisation in cavity : 98.0719
Photodiode 1 after Wollaston prism : 0.674538
Photodiode 2 after Wollaston prism : 69.2957
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot2 Ch9 : -1589.4
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : -0.179
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.13
Left Arm Q1 momentum : 3.14108
Left Arm Q1 gauss meter : -0.1994
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.79
Left Arm Q2 momentum : 3.14164
Left Arm Q2 gauss meter : 0.7106
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1103.83
Left Arm D1 momentum : 3.14166
Left Arm D1 NMR : 1.1634
Left Arm Q3 power supply current : 1250.88
Left Arm Q3 momentum : 3.14199
Left Arm Q3 gauss meter : -0.63111
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.12
Right Arm Q1 momentum : 3.14139
Right Arm Q1 gauss meter : -0.05865
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1351.91
Right Arm Q2 momentum : 3.14129
Right Arm Q2 gauss meter : 0.7062
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.85
Right Arm D1 momentum : 3.14155
Right Arm D1 NMR : 1.16579
Right Arm Q3 power supply current : 1250.02
Right Arm Q3 momentum : 3.14148
Right Arm Q3 gauss meter : 0.5593
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.41602
Right Arm Top VDC Current : -1.66016
Right Arm Bottom VDC Current : -1.36719
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.0185547
Right Arm Top VDC voltage : -0.0117188
Right Arm Bottom VDC voltage : -0.00878906
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 5.59542
Current on Unser monitor : -1.74775
Current on Upstream bcm : 5.47079
Current on Downstream bcm : 5.72005
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 13.0067
Tiefenbach Hall A energy : 3483.12
Tiefenbach Hall C energy : 2344.14
Delta(E)/E width (MV_AI_DXWID) : 3.89733
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.327013
IPM1C12.YPOS : 0.233689
IPM1H04A.XPOS : -0.309942
IPM1H04A.YPOS : 1.0859
IPM1H04B.XPOS : -0.789833
IPM1H04B.YPOS : 1.94727
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.327013
Survey Y offset bpm12 : 0.233689
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619678
HacL_HPE1313A:0_Ch58 : -0.20459
HacL_HPE1313A:0_Ch55 : 22.8516
HacL_HPE1313A:0_Ch54 : 0.019043
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.0232422
HacR_HPE1313A:0_Ch58 : -0.626953
HacR_HPE1313A:0_Ch55 : 22.168
HacR_HPE1313A:0_Ch54 : -0.96582
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 72
Encoder position : 17740750
temperature loop 3-1 : 19.02
temperature loop 3-2 : 19.02
temperature loop 3-3 : 0.9
pressure fill target H2 : 28.1712
pressure fill bottle H2 : 28.4596
pressure ballast H2 : 28.5328
pressure exhaust H2 : 28.1163
cryogen input temp : 13.7
crogen return flow : 24.6622
JT valve setting : 53.0762
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 12633 -d '2009-09-24 09:14:18' -t 17740750 -s IN