    User name R. Michaels

    Log entry time 04:25:16 on November 6,2009

    Entry number 297714

    Followups:

    keyword=Qsq runs (L-HRS only)

    04:09 ... Start Qsq measurement on L-HRS.

    L-HRS has recovered. P0=3.66 GeV
    Ask for 2 uA on LD2. VDCs turned on.

    Rates
    T1 = 8800 Hz
    T2 = 85 Hz
    T3 = 1775 Hz
    T4 = 1743 Hz
    T5 = 2200 Hz
    T6 = 100 Hz
    T7 = 12.9 kHz

    Adjusting prescales to keep 200 Hz. Expect deadtime due to FADC.
    ps1=60,ps2=20,ps3=100,ps4=100,ps5=100,ps6=20,ps7=500,ps8=65535

    Actually deadtime is zero. Oops! FADC is not in datastream yet.

    Run 25249 is at 220 Hz.

    Do another run with ps1=10 and others "infinite" to reduce
    the trigger bias.

    Run 25250 at 800 Hz.

    04:24 ... Stop Qsq measurements. VDCs turned off.
    Ask for higher current to complete the target boiling tests.