Log entry time 05:43:50 on November 10, 2009
Entry number 298718
keyword=End_of_Parity_Run_13864__CODA_Config=Pvdis
************************************************
Run Number: 13864
End of Run Comment:
Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=production,dithering_magnet=off,dithering_magnets=,leftarm_p=3.66,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 13864 at Tue Nov 10 05:43:45 EST 2009
CODA Configuration: Pvdis
Compton Run Number : 20912
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1724.8
Wien field : 49.796
Laser attenuation Hall A : 122
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.3
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.2
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.743
Gun2: PC (PITA) NEG : 6.957
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.75092
Pockels Cell Voltage NEG : 1.55311
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 0.827411
Photodiode on table : 385.344
Laser X position on QPD 1 : 124.843
Laser Y position on QPD 1 : 512.092
Laser X position on QPD 2 : 15.5689
Laser Y position on QPD 2 : -604.196
QPD 1 sum : -1.5748
QPD 2 sum : -1.20369
Position set point for adjustable
mirror 1 (either x or y) : -1520[c]
Position set point for adjustable
mirror 2 (either x or y) : -1420[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2250
Polarisation in cavity : LEFT
Reflection photodiode : 0.869804
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : -1.86962
Calculated polarisation in cavity : 33.8377
Photodiode 1 after Wollaston prism : 0.0262383
Photodiode 2 after Wollaston prism : 0.0437612
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.05
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 2754.18
Left Arm Q1 momentum : 3.66078
Left Arm Q1 gauss meter : -0.23216
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1575.82
Left Arm Q2 momentum : 3.65959
Left Arm Q2 gauss meter : 0.8273
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -0.00329923
Left Arm D1 momentum : 0.000379423
Left Arm D1 NMR : 1.39509
Left Arm Q3 power supply current : 1457.19
Left Arm Q3 momentum : 3.66019
Left Arm Q3 gauss meter : -0.73454
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1977.7
Right Arm Q1 momentum : 2.63015
Right Arm Q1 gauss meter : -0.04915
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1132.09
Right Arm Q2 momentum : 2.63052
Right Arm Q2 gauss meter : 0.5924
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 931.954
Right Arm D1 momentum : 2.63003
Right Arm D1 NMR : 0.975971
Right Arm Q3 power supply current : 1046.45
Right Arm Q3 momentum : 2.62987
Right Arm Q3 gauss meter : 0.4682
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 89.4483
Current on Unser monitor : 106.557
Current on Upstream bcm : 87.1511
Current on Downstream bcm : 91.7454
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 89.6951
Tiefenbach Hall A energy : 6067.35
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.0548405
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0.0134172
IPM1C12.YPOS : 0.158525
IPM1H04A.XPOS : -0.189209
IPM1H04A.YPOS : -0.123593
IPM1H04B.XPOS : -0.00116771
IPM1H04B.YPOS : -0.0201734
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : -0.0110406
Survey Y offset bpm12 : 0.17166
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077688
fan frequency loop 1 : 59.5
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.47
temperature loop 1-2 : 22.39
temperature loop 1-3 : 22.95
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 25.4856
pressure fill bottle H2 : 25.7374
pressure ballast H2 : 25.3712
pressure exhaust H2 : 24.5014
cryogen input temp : 218.5
crogen return flow : 0.257662
JT valve setting : -0.683594
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_13864.log:
Cumulative stats for 99809 events:
Events failing cut conditions:
0 Low_beam 18528
1 Beam_burp 218
2 Evt_seq 0
3 Pair_seq 923
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------