    User name D.Wang/R.Subedi

    Log entry time 16:20:00 on November 26, 2009

    Entry number 302830

    keyword=access work

    We changed the widths of some signals for the veto circuit for both arms.
    All these changes are done without change the timing of the signals.

    Left arm:
    changed the input T1 width to 30ns by moving it from the NIM-ECL module
    to a discriminator.
    changed the output width of T1's 755 to 32 ns.
    Measured the input GC width, which is 60 ns.
    changed the output width of GC's 755 to 70ns.

    Right arm:
    changed the input T1 width to 30ns (by removing an 8ns cable and then
    plugging it into a discriminator).
    changed the output width of T1's 755 to 32 ns.
    Measured the input GC width, which was 100 ns. Then we changed it to 60ns
    by adjusting the module's width for GC upstairs.