    User name apar

    Log entry time 07:09:12 on December 4, 2009

    Entry number 304567

    keyword=End_of_Parity_Run_14408__CODA_Config=Pvdis
    ************************************************
     Run Number: 14408
     End of Run Comment:
    
    Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=production,dithering_magnet=on,dithering_magnets=,leftarm_p=3.66,leftarm_theta=15,parity_feedback=on,parity_ihwp=in,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
    ************************************************
    End-of-Parity-run EPICS data for Run Number 14408 at Fri Dec  4 07:09:05 EST 2009
    CODA Configuration: Pvdis
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 21394
    -----------------------------------------
    Wien angle                               : 74.7279
    Wien BDL                                 : 1730
    Wien field                               : 49.796
    Laser attenuation Hall A                 : 224
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.87
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5.15
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.036
    Gun2: PC (PITA) NEG                      : 6.664
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 1.76313
    Pockels Cell Voltage NEG                 : 1.55311
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 cycles
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 cycles
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr746mW
    Calculated power in cavity               : 728.326
    Photodiode on table                      : 382.602
    Laser X position on QPD 1                : 116.709
    Laser Y position on QPD 1                : 518.626
    Laser X position on QPD 2                : 13.1872
    Laser Y position on QPD 2                : -618.681
    QPD 1 sum                                : -1.33187
    QPD 2 sum                                : -1.09626
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -1645[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -1000[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.1344
    Polarisation in cavity                   : LEFT
    Reflection photodiode                    : 0.465727
    Gain of locking servo                    : 131.122
    Tracking level (V) of locking servo      : 0.60975
    Slow locking signal sent to laser        : 0.368064
    Fast locking signal sent to laser        : -8.01502
    Calculated polarisation in cavity        : 97.7602
    Photodiode 1 after Wollaston prism       : 0.644632
    Photodiode 2 after Wollaston prism       : 56.8323
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 2753.59
    Left Arm Q1 momentum                     : 3.66007
    Left Arm Q1 gauss meter                  : -0.23208
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1575.78
    Left Arm Q2 momentum                     : 3.65951
    Left Arm Q2 gauss meter                  : 0.8272
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1321.52
    Left Arm D1 momentum                     : 3.6599
    Left Arm D1 NMR                          : 1.35571
    Left Arm Q3 power supply current         : 1457.25
    Left Arm Q3 momentum                     : 3.66034
    Left Arm Q3 gauss meter                  : -0.73465
    Left Arm Q3 power supply polarity        : disabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 1977.86
    Right Arm Q1 momentum                    : 2.63036
    Right Arm Q1 gauss meter                 : -0.04913
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1131.93
    Right Arm Q2 momentum                    : 2.63016
    Right Arm Q2 gauss meter                 : 0.5921
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 931.827
    Right Arm D1 momentum                    : 2.63002
    Right Arm D1 NMR                         : 0.975971
    Right Arm Q3 power supply current        : 1046.58
    Right Arm Q3 momentum                    : 2.63019
    Right Arm Q3 gauss meter                 : 0.4683
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 95.3442
    Current on Unser monitor                 : 113.712
    Current on Upstream bcm                  : 93.0168
    Current on Downstream bcm                : 97.6717
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 95.9442
    Tiefenbach Hall A energy                 : 6067.37
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 0.0589516
    MBSY1c Hall A Beam energy                : 6081.48
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 254.343
    MBSY1c Bdl                               : 1.51764e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0.0181324
    IPM1C12.YPOS                             : 0.142266
    IPM1H04A.XPOS                            : -0.682971
    IPM1H04A.YPOS                            : 0.0189673
    IPM1H04B.XPOS                            : -0.686743
    IPM1H04B.YPOS                            : 0.0276168
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0.0181324
    Survey Y offset bpm12                     : 0.142266
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L1 20cm
    Encoder position                         : 33077690
    fan frequency loop 1                     : 60
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 22.5
    temperature loop 1-2                     : 22.07
    temperature loop 1-3                     : 22.62
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 99.99
    temperature loop 3-2                     : 99.99
    temperature loop 3-3                     : 29.99
    pressure fill target H2                  : 25.0767
    pressure fill bottle H2                  : 25.6107
    pressure ballast H2                      : 25.0965
    pressure exhaust H2                      : 25.42
    cryogen input temp                       : 218.7
    crogen return flow                       : 0.490305
     JT valve setting                        : -0.390625
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_14408.log:
    
       Cumulative stats for 99815 events: 
       
       Events failing cut conditions:
       0         Low_beam  26389
       1        Beam_burp    327
       2          Evt_seq      0
       3         Pair_seq      1
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------