User name apar
Log entry time 06:32:07 on December 8, 2009
Entry number 305550
keyword=End_of_Parity_Run_14510__CODA_Config=Pvdis
************************************************
Run Number: 14510
End of Run Comment:
Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=Production,dithering_magnet=on,dithering_magnets=,leftarm_p=2.63,leftarm_theta=20,parity_feedback=on,parity_ihwp=in,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 14510 at Tue Dec 8 06:32:02 EST 2009
CODA Configuration: Pvdis
Compton Run Number : 21452
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1730
Wien field : 49.796
Laser attenuation Hall A : 118
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.1
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.934
Gun2: PC (PITA) NEG : 6.766
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.01709
Pockels Cell Voltage NEG : 1.82418
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 718.952
Photodiode on table : 380.857
Laser X position on QPD 1 : 112.83
Laser Y position on QPD 1 : 523.19
Laser X position on QPD 2 : 13.7062
Laser Y position on QPD 2 : -621.21
QPD 1 sum : -1.27205
QPD 2 sum : -1.05597
Position set point for adjustable
mirror 1 (either x or y) : -1645[c]
Position set point for adjustable
mirror 2 (either x or y) : -1000[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2438
Polarisation in cavity : LEFT
Reflection photodiode : 0.419337
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.708661
Fast locking signal sent to laser : -1.39352
Calculated polarisation in cavity : 97.686
Photodiode 1 after Wollaston prism : 0.65743
Photodiode 2 after Wollaston prism : 56.1649
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 1978.77
Left Arm Q1 momentum : 2.63025
Left Arm Q1 gauss meter : -0.16683
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1132.48
Left Arm Q2 momentum : 2.63002
Left Arm Q2 gauss meter : 0.5955
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 908.442
Left Arm D1 momentum : 2.63004
Left Arm D1 NMR : 0.973562
Left Arm Q3 power supply current : 1047.08
Left Arm Q3 momentum : 2.63006
Left Arm Q3 gauss meter : -0.52832
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1977.86
Right Arm Q1 momentum : 2.63036
Right Arm Q1 gauss meter : -0.04912
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1131.93
Right Arm Q2 momentum : 2.63014
Right Arm Q2 gauss meter : 0.592
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 931.858
Right Arm D1 momentum : 2.63004
Right Arm D1 NMR : 0.975978
Right Arm Q3 power supply current : 1046.58
Right Arm Q3 momentum : 2.63019
Right Arm Q3 gauss meter : 0.4683
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 22.3541
Current on Unser monitor : 39.8233
Current on Upstream bcm : 21.8298
Current on Downstream bcm : 22.8783
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 22.3007
Tiefenbach Hall A energy : 6068.43
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.251276
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : -0.616215
IPM1C12.YPOS : 0.288594
IPM1H04A.XPOS : -0.757001
IPM1H04A.YPOS : -0.00291997
IPM1H04B.XPOS : -0.708597
IPM1H04B.YPOS : -0.0385031
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : -0.184969
Survey Y offset bpm12 : 0.113497
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Clear
Encoder position : 33077692
fan frequency loop 1 : 60
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.45
temperature loop 1-2 : 22.01
temperature loop 1-3 : 22.36
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 25.127
pressure fill bottle H2 : 25.8503
pressure ballast H2 : 24.416
pressure exhaust H2 : 25.3712
cryogen input temp : 216.7
crogen return flow : 0.561264
JT valve setting : -0.292969
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_14510.log:
Cumulative stats for 99809 events:
Events failing cut conditions:
0 Low_beam 24611
1 Beam_burp 220
2 Evt_seq 0
3 Pair_seq 0
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------