    User name pking

    Log entry time 16:23:28 on December 08, 2009

    Entry number 305639

    This entry is a followup to: 305626

    Followups:

    keyword=Replaced batteries for INJ null asymmetry test

    We have changed the batteries being read out as a null asymmetry test in the injector.

    The run right before is 14518 (5k events), the run right after is 14519 (> 5k events). Run 14520 was a second test run.

    The battery numbers in the chart below are in the physical order on the panel in the INJ service building; battery_1 is the left-most, and battery_4 is the right-most.

                          battery_3    battery_4    battery_1    battery_2
    Run #      # events   (volt)       (volt)       (volt)       (volt)
    14518       5043      2.61896      2.61666      2.57798      0.225905
    14519      15193      3.19623      3.18448      3.14008      3.16446
    14520       9577      3.19495      3.18322      3.13879      3.16316
    

    The cells from battery_2 showed some corrosion when we removed them.

    While changing the batteries, I noticed a dangling ECL cable. I think that this cable was used as the trigger input for stand-alone tests of the Qweak crate, and should be unused currently; I am rechecking the circuit.