Log entry time 00:57:03 on December 19, 2009
Entry number 308039
keyword=End_of_Parity_Run_14762__CODA_Config=Pvdis
************************************************
Run Number: 14762
End of Run Comment:
Run_type=Production,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=production,dithering_magnet=on,dithering_magnets=,leftarm_p=4868,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=in,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 14762 at Sat Dec 19 00:56:56 EST 2009
CODA Configuration: Pvdis
Compton Run Number : 21665
-----------------------------------------
Wien angle : 90.4685
Wien BDL : 2098.1
Wien field : 60.306
Laser attenuation Hall A : 195
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.205
Gun2: PC (PITA) NEG : 6.495
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00488
Pockels Cell Voltage NEG : 1.8486
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 0.176567
Photodiode on table : 388.833
Laser X position on QPD 1 : 163.796
Laser Y position on QPD 1 : 483.814
Laser X position on QPD 2 : -14.6494
Laser Y position on QPD 2 : -602.971
QPD 1 sum : -1.6566
QPD 2 sum : -1.20613
Position set point for adjustable
mirror 1 (either x or y) : -2335[c]
Position set point for adjustable
mirror 2 (either x or y) : -3805[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1715
Polarisation in cavity : RIGHT
Reflection photodiode : 0.830739
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.66
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 1.98315
Calculated polarisation in cavity : 12.4505
Photodiode 1 after Wollaston prism : 0.00746988
Photodiode 2 after Wollaston prism : 0.00581575
Step size for RHWP scan : 11162
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 3009.67
Left Arm Q1 momentum : 4.00046
Left Arm Q1 gauss meter : -0.25343
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1576.06
Left Arm Q2 momentum : 3.66015
Left Arm Q2 gauss meter : 0.8273
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1498.43
Left Arm D1 momentum : 3.99989
Left Arm D1 NMR : 1.48186
Left Arm Q3 power supply current : 1457.2
Left Arm Q3 momentum : 3.66021
Left Arm Q3 gauss meter : -0.73454
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 2331.57
Right Arm Q1 momentum : 3.10083
Right Arm Q1 gauss meter : -0.05786
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1334.12
Right Arm Q2 momentum : 3.09995
Right Arm Q2 gauss meter : 0.6974
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1118.9
Right Arm D1 momentum : 3.1
Right Arm D1 NMR : 1.15037
Right Arm Q3 power supply current : 1233.47
Right Arm Q3 momentum : 3.09987
Right Arm Q3 gauss meter : 0.5519
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 98.1768
Current on Unser monitor : 116.958
Current on Upstream bcm : 95.727
Current on Downstream bcm : 100.626
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 98.6889
Tiefenbach Hall A energy : 4867.38
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.581957
MBSY1c Hall A Beam energy : 4877.58
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 203.554
MBSY1c Bdl : 1.21721e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0.00687772
IPM1C12.YPOS : -0.366723
IPM1H04A.XPOS : -0.688948
IPM1H04A.YPOS : -0.0257843
IPM1H04B.XPOS : -0.697285
IPM1H04B.YPOS : 0.0148563
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.00687772
Survey Y offset bpm12 : -0.365486
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077692
fan frequency loop 1 : 60
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 23.64
temperature loop 1-2 : 22.07
temperature loop 1-3 : 22.64
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 25.2659
pressure fill bottle H2 : 25.4322
pressure ballast H2 : 25.8549
pressure exhaust H2 : 25.1987
cryogen input temp : 217
crogen return flow : 0.483954
JT valve setting : -0.390625
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_14762.log:
Cumulative stats for 99750 events:
Events failing cut conditions:
0 Low_beam 21522
1 Beam_burp 310
2 Evt_seq 0
3 Pair_seq 0
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------