• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 02:16:46 on December 20, 2009

    Entry number 308340

    keyword=End_of_Parity_Run_14784__CODA_Config=Pvdis
    ************************************************
     Run Number: 14784
     End of Run Comment:
    
    Run_type=Other,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=Oversampling test on tantalum target (oversampling '3'),dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=Thick Tantalum
    ************************************************
    End-of-Parity-run EPICS data for Run Number 14784 at Sun Dec 20 02:16:37 EST 2009
    CODA Configuration: Pvdis
    
    # Timing board information: # Integrate Time = 8.00 ms, Ramp Delay = 0.00 us oversamp 4
    
    Compton Run Number                       : 21678
    -----------------------------------------
    Wien angle                               : 90.4685
    Wien BDL                                 : 2098.1
    Wien field                               : 60.306
    Laser attenuation Hall A                 : 231
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.87
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 7.83
    Gun2: PC (PITA) NEG                      : 6.87
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 1.78266
    Pockels Cell Voltage NEG                 : 1.56532
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 cycles
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 cycles
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr741mW
    Calculated power in cavity               : 825.896
    Photodiode on table                      : 382.602
    Laser X position on QPD 1                : 170.361
    Laser Y position on QPD 1                : 479.511
    Laser X position on QPD 2                : -14.8296
    Laser Y position on QPD 2                : -599.179
    QPD 1 sum                                : -1.6627
    QPD 2 sum                                : -1.19148
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -2335[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : 100[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.0987
    Polarisation in cavity                   : LEFT
    Reflection photodiode                    : 0.343649
    Gain of locking servo                    : 168
    Tracking level (V) of locking servo      : 0.66
    Slow locking signal sent to laser        : 0.0640907
    Fast locking signal sent to laser        : 9.89745
    Calculated polarisation in cavity        : 97.7801
    Photodiode 1 after Wollaston prism       : 0.724525
    Photodiode 2 after Wollaston prism       : 64.5501
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 2670.76
    Left Arm Q1 momentum                     : 3.54997
    Left Arm Q1 gauss meter                  : -0.22505
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1528.48
    Left Arm Q2 momentum                     : 3.54964
    Left Arm Q2 gauss meter                  : 0.8025
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1269.93
    Left Arm D1 momentum                     : 3.54992
    Left Arm D1 NMR                          : 1.3149
    Left Arm Q3 power supply current         : 1412.87
    Left Arm Q3 momentum                     : 3.54887
    Left Arm Q3 gauss meter                  : -0.71228
    Left Arm Q3 power supply polarity        : disabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 2331.3
    Right Arm Q1 momentum                    : 3.10041
    Right Arm Q1 gauss meter                 : -0.05785
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1334.13
    Right Arm Q2 momentum                    : 3.09997
    Right Arm Q2 gauss meter                 : 0.6974
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 1118.97
    Right Arm D1 momentum                    : 3.10003
    Right Arm D1 NMR                         : 1.15038
    Right Arm Q3 power supply current        : 1233.46
    Right Arm Q3 momentum                    : 3.09986
    Right Arm Q3 gauss meter                 : 0.5519
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 99.2207
    Current on Unser monitor                 : 118.604
    Current on Upstream bcm                  : 96.8118
    Current on Downstream bcm                : 101.63
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 99.7628
    Tiefenbach Hall A energy                 : 4867.41
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 0.593617
    MBSY1c Hall A Beam energy                : 4877.58
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 203.554
    MBSY1c Bdl                               : 1.21721e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : -0.0217015
    IPM1C12.YPOS                             : -0.434248
    IPM1H04A.XPOS                            : -0.732534
    IPM1H04A.YPOS                            : 0.0249507
    IPM1H04B.XPOS                            : -0.701711
    IPM1H04B.YPOS                            : 0.0134873
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : -0.0217015
    Survey Y offset bpm12                     : -0.434248
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : Thick Tantalum
    Encoder position                         : 6128624
    fan frequency loop 1                     : 14.5
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 29.46
    temperature loop 1-2                     : 29.41
    temperature loop 1-3                     : 33.71
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 0
    temperature loop 3-2                     : 0
    temperature loop 3-3                     : 0
    pressure fill target H2                  : 25.6489
    pressure fill bottle H2                  : 25.6092
    pressure ballast H2                      : 25.9113
    pressure exhaust H2                      : 25.4429
    cryogen input temp                       : 211.8
    crogen return flow                       : 0.332305
     JT valve setting                        : -0.146484
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_14784.log:
    
       Cumulative stats for 33766 events: 
       
       Events failing cut conditions:
       0         Low_beam   7047
       1        Beam_burp      2
       2          Evt_seq      0
       3         Pair_seq      0
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------