Make Followup Entry
User name apar
Log entry time 04:37:25 on December 20, 2009
Entry number 308371
keyword=End_of_Parity_Run_14793__CODA_Config=Pvdis
************************************************
Run Number: 14793
End of Run Comment:
Run_type=Other,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=Low current cavity test,dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=Thick Tantalum
************************************************
End-of-Parity-run EPICS data for Run Number 14793 at Sun Dec 20 04:37:18 EST 2009
CODA Configuration: Pvdis
Compton Run Number : 21678
-----------------------------------------
Wien angle : 90.4685
Wien BDL : 2098.1
Wien field : 60.306
Laser attenuation Hall A : 65
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.823
Gun2: PC (PITA) NEG : 6.877
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.01954
Pockels Cell Voltage NEG : 1.8486
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : 3
Pwr752mW
Calculated power in cavity : 0.164178
Photodiode on table : 382.602
Laser X position on QPD 1 : 171.685
Laser Y position on QPD 1 : 477.792
Laser X position on QPD 2 : -15.6005
Laser Y position on QPD 2 : -595.211
QPD 1 sum : -1.6688
QPD 2 sum : -1.20125
Position set point for adjustable
mirror 1 (either x or y) : -2335[c]
Position set point for adjustable
mirror 2 (either x or y) : 100[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1413
Polarisation in cavity : LEFT
Reflection photodiode : 0.830739
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.66
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 2.45559
Calculated polarisation in cavity : 15.1357
Photodiode 1 after Wollaston prism : 0.00746988
Photodiode 2 after Wollaston prism : 0.0055059
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 2670.76
Left Arm Q1 momentum : 3.54997
Left Arm Q1 gauss meter : -0.22504
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1528.48
Left Arm Q2 momentum : 3.54966
Left Arm Q2 gauss meter : 0.8025
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1269.93
Left Arm D1 momentum : 3.54992
Left Arm D1 NMR : 1.31489
Left Arm Q3 power supply current : 1412.89
Left Arm Q3 momentum : 3.54891
Left Arm Q3 gauss meter : -0.71229
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 2331.3
Right Arm Q1 momentum : 3.10041
Right Arm Q1 gauss meter : -0.05786
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1334.13
Right Arm Q2 momentum : 3.09998
Right Arm Q2 gauss meter : 0.6974
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1118.97
Right Arm D1 momentum : 3.09995
Right Arm D1 NMR : 1.15035
Right Arm Q3 power supply current : 1233.47
Right Arm Q3 momentum : 3.09989
Right Arm Q3 gauss meter : 0.5519
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 1.13915
Current on Unser monitor : 21.05
Current on Upstream bcm : 1.10555
Current on Downstream bcm : 1.17275
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 1.26336
Tiefenbach Hall A energy : 4866.74
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.594699
MBSY1c Hall A Beam energy : 4877.58
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 203.554
MBSY1c Bdl : 1.21721e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : -0.713641
IPM1H04A.YPOS : -0.0359328
IPM1H04B.XPOS : -0.697266
IPM1H04B.YPOS : -0.0635407
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Thick Tantalum
Encoder position : 6128624
fan frequency loop 1 : 14
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 33.51
temperature loop 1-2 : 33.57
temperature loop 1-3 : 41.55
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 25.3208
pressure fill bottle H2 : 25.362
pressure ballast H2 : 25.9037
pressure exhaust H2 : 24.4236
cryogen input temp : 216.7
crogen return flow : 0
JT valve setting : -0.0976562
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_14793.log:
Cumulative stats for 9074 events:
Events failing cut conditions:
0 Low_beam 9074
1 Beam_burp 0
2 Evt_seq 0
3 Pair_seq 0
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------