User name apar
Log entry time 06:17:14 on December 20, 2009
Entry number 308429
keyword=End_of_Parity_Run_14796__CODA_Config=Pvdis
************************************************
Run Number: 14796
End of Run Comment:
Run_type=Other,beam_energy=4.87,beam_polarization=87,beam_raster=off,comment_text=Low current cavity test (@ 0.5uA, Raster Off),dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=Thick Tantalum
************************************************
End-of-Parity-run EPICS data for Run Number 14796 at Sun Dec 20 06:17:07 EST 2009
CODA Configuration: Pvdis
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 21678
-----------------------------------------
Wien angle : 90.4685
Wien BDL : 2098.1
Wien field : 60.306
Laser attenuation Hall A : 62
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.823
Gun2: PC (PITA) NEG : 6.877
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.99756
Pockels Cell Voltage NEG : 1.83883
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 0.173105
Photodiode on table : 392.323
Laser X position on QPD 1 : 166.936
Laser Y position on QPD 1 : 480.08
Laser X position on QPD 2 : -14.3446
Laser Y position on QPD 2 : -598.595
QPD 1 sum : -1.67735
QPD 2 sum : -1.23176
Position set point for adjustable
mirror 1 (either x or y) : -2335[c]
Position set point for adjustable
mirror 2 (either x or y) : 100[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1830
Polarisation in cavity : LEFT
Reflection photodiode : 0.817311
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.66
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : -5.16572
Calculated polarisation in cavity : 17.3527
Photodiode 1 after Wollaston prism : 0.00781794
Photodiode 2 after Wollaston prism : 0.0055059
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.00043966
Left Arm Q1 gauss meter : 0.0002809
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.0154207
Left Arm Q2 momentum : 0.00327249
Left Arm Q2 gauss meter : 0.000896
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.36789
Left Arm D1 momentum : 0.000865184
Left Arm D1 NMR : 0.39975
Left Arm Q3 power supply current : -0.00578525
Left Arm Q3 momentum : -1.45504e-05
Left Arm Q3 gauss meter : 3.712e-05
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0.16022
Right Arm Q1 momentum : 0.00129374
Right Arm Q1 gauss meter : -4.44e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.00712118
Right Arm Q2 momentum : -1.60656e-05
Right Arm Q2 gauss meter : 0.0003778
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1.89188
Right Arm D1 momentum : 0.00283542
Right Arm D1 NMR : 0.17736
Right Arm Q3 power supply current : 0.000934076
Right Arm Q3 momentum : 0.000132654
Right Arm Q3 gauss meter : -0.0002763
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.589258
Current on Unser monitor : 20.1608
Current on Upstream bcm : 0.575962
Current on Downstream bcm : 0.602554
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.914272
Tiefenbach Hall A energy : 4867.03
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.591846
MBSY1c Hall A Beam energy : 4877.58
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 203.554
MBSY1c Bdl : 1.21721e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : -1.3608
IPM1C12.YPOS : -0.109961
IPM1H04A.XPOS : -0.442466
IPM1H04A.YPOS : -0.395481
IPM1H04B.XPOS : 1.35999
IPM1H04B.YPOS : -1.18498
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : -1.4506
Survey Y offset bpm12 : -0.0944788
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Thick Tantalum
Encoder position : 6128624
fan frequency loop 1 : 14.5
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 28.02
temperature loop 1-2 : 27.95
temperature loop 1-3 : 28.29
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 25.0965
pressure fill bottle H2 : 25.1286
pressure ballast H2 : 25.8824
pressure exhaust H2 : 24.9134
cryogen input temp : 217.9
crogen return flow : 0.328941
JT valve setting : -0.0488281
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_14796.log:
Cumulative stats for 35305 events:
Events failing cut conditions:
0 Low_beam 35305
1 Beam_burp 0
2 Evt_seq 0
3 Pair_seq 0
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------