NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 13:01:27 on February 26, 2010
Entry number 310040
keyword=End_of_Parity_Run_1458__CODA_Config=CHInj2
************************************************
Run Number: 1458
End of Run Comment:
Run_type=Parityscan,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=Injector Laser Studies::test,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=out,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 1458 at Fri Feb 26 13:01:20 EST 2010
CODA Configuration: CHInj2
# Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 0
-----------------------------------------
Wien angle : 0
Wien BDL : 2098.1
Wien field : 54.162
Laser attenuation Hall A : 76
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 9000
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5.682
Gun2: PC (PITA) NEG : 6.001
Gun3: PC (PITA) POS : 5
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 0
Pockels Cell Voltage NEG : 0
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 windows
Helicity Pattern Set : Pair
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 windows
Helicity Pattern Read : Pair
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power :
Calculated power in cavity : 1.14493
Photodiode on table : -0.041999
Laser X position on QPD 1 : -147.891
Laser Y position on QPD 1 : -81.7031
Laser X position on QPD 2 : 7.18684e+06
Laser Y position on QPD 2 : 442.478
QPD 1 sum : -0.00366241
QPD 2 sum : -7.45058e-08
Position set point for adjustable
mirror 1 (either x or y) : 2320[c]
Position set point for adjustable
mirror 2 (either x or y) : 55020[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point :
Polarisation in cavity : RIGHT
Reflection photodiode : 0.00427268
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.0128181
Fast locking signal sent to laser : 0.00549339
Calculated polarisation in cavity : 30.7779
Photodiode 1 after Wollaston prism : 0.05917
Photodiode 2 after Wollaston prism : 0.0313193
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0.0534066
Left Arm Q1 momentum : 0.00058517
Left Arm Q1 gauss meter : 0.0002716
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : -0.000314479
Left Arm Q2 momentum : -7.05049e-07
Left Arm Q2 gauss meter : 0.0010522
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00217685
Left Arm D1 momentum : 0.0025524
Left Arm D1 NMR : 0.270415
Left Arm Q3 power supply current : -0.000601847
Left Arm Q3 momentum : -1.26898e-06
Left Arm Q3 gauss meter : -0.00012407
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.00159597
Right Arm Q1 gauss meter : -3.87e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.000147896
Right Arm Q2 momentum : -3.23287e-07
Right Arm Q2 gauss meter : 0.0005392
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00333594
Right Arm D1 momentum : 0.00465402
Right Arm D1 NMR : 6.85943
Right Arm Q3 power supply current : 0.00014198
Right Arm Q3 momentum : 0.001926
Right Arm Q3 gauss meter : 4.41e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0232066
Current on Unser monitor : 18.2885
Current on Upstream bcm : 0.0341271
Current on Downstream bcm : 0.0122861
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.0019283
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 0
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 24271.1
MBSY3c Hall C Beam energy : 8874.29
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 6.05688e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 0
Raster Y width : 0
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.3816
pressure fill bottle H2 : 14.3572
pressure ballast H2 : 24.2069
pressure exhaust H2 : 14.406
cryogen input temp : 299.8
crogen return flow : 0
JT valve setting : 98.3398
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_1458.log:
Cumulative stats for 3103 events:
Events failing cut conditions:
0 Low_beam 3103
1 Beam_burp 0
2 Evt_seq 0
3 Pair_seq 0
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------