• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name R. Michaels

    Log entry time 10:22:38 on March 2,2010

    Entry number 310390

    Followups:

    keyword=DAQ tests on adaql5, part 1

    Ran Parity DAQ on adaql5 with ET buffer larger 
    (ET_CHUNK_SIZE = 500, it is usually only 50).  
    We see 180 - 240Hz now. 
    
    [apar@adaql2 ~/prex/feedback/runlog]$ grep Hz ffb_50804.log
    ET rate 10.4 Hz in  5 sec, avg 10.4 Hz
    ET rate 220.0 Hz in  5 sec, avg 115.2 Hz
    ET rate 210.2 Hz in  5 sec, avg 146.9 Hz
    ET rate 220.0 Hz in  5 sec, avg 165.2 Hz
    ET rate 160.0 Hz in  5 sec, avg 164.1 Hz
    ET rate 230.2 Hz in  5 sec, avg 175.1 Hz
    ET rate 160.0 Hz in  5 sec, avg 173.0 Hz
    ET rate 220.2 Hz in  5 sec, avg 178.9 Hz
    ET rate 160.0 Hz in  5 sec, avg 176.8 Hz
    ET rate 240.0 Hz in  5 sec, avg 183.1 Hz
    ET rate 180.2 Hz in  5 sec, avg 182.8 Hz
    ET rate 200.0 Hz in  5 sec, avg 184.3 Hz
    
    ROC6 crashed hard.  Rupesh is climbing there to reset it.
    Found out the R-HRS is being serviced -- fix some 
    electrical breakers.  Bad luck !