NEXT
Make New Entry,
Make Followup Entry
User name R. Michaels
Log entry time 10:22:38 on March 2,2010
Entry number 310390
Followups:
keyword=DAQ tests on adaql5, part 1
Ran Parity DAQ on adaql5 with ET buffer larger
(ET_CHUNK_SIZE = 500, it is usually only 50).
We see 180 - 240Hz now.
[apar@adaql2 ~/prex/feedback/runlog]$ grep Hz ffb_50804.log
ET rate 10.4 Hz in 5 sec, avg 10.4 Hz
ET rate 220.0 Hz in 5 sec, avg 115.2 Hz
ET rate 210.2 Hz in 5 sec, avg 146.9 Hz
ET rate 220.0 Hz in 5 sec, avg 165.2 Hz
ET rate 160.0 Hz in 5 sec, avg 164.1 Hz
ET rate 230.2 Hz in 5 sec, avg 175.1 Hz
ET rate 160.0 Hz in 5 sec, avg 173.0 Hz
ET rate 220.2 Hz in 5 sec, avg 178.9 Hz
ET rate 160.0 Hz in 5 sec, avg 176.8 Hz
ET rate 240.0 Hz in 5 sec, avg 183.1 Hz
ET rate 180.2 Hz in 5 sec, avg 182.8 Hz
ET rate 200.0 Hz in 5 sec, avg 184.3 Hz
ROC6 crashed hard. Rupesh is climbing there to reset it.
Found out the R-HRS is being serviced -- fix some
electrical breakers. Bad luck !