NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 17:50:48 on March 3, 2010
Entry number 310553
keyword=End_of_Parity_Run_1620__CODA_Config=CHInj2
************************************************
Run Number: 1620
End of Run Comment:
Run_type=Test,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=Source Studies:: horizontal lina,analyzer in, horizontal lina scan,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=out,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 1620 at Wed Mar 3 17:50:41 EST 2010
CODA Configuration: CHInj2
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 22110
-----------------------------------------
Wien angle : -1.3054
Wien BDL : 2149
Wien field : 55.48
Laser attenuation Hall A : 70
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.476
Gun2: PC (PITA) NEG : 7.796
Gun3: PC (PITA) POS : 5
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.55433
Pockels Cell Voltage NEG : 2.39072
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 windows
Helicity Pattern Set : Pair
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 windows
Helicity Pattern Read : Pair
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 95mW
Calculated power in cavity : 1.1298
Photodiode on table : 591.226
Laser X position on QPD 1 : 665.45
Laser Y position on QPD 1 : -65.3627
Laser X position on QPD 2 : 128.009
Laser Y position on QPD 2 : -696.656
QPD 1 sum : -0.00244163
QPD 2 sum : -1.04987
Position set point for adjustable
mirror 1 (either x or y) : -1120000[c]
Position set point for adjustable
mirror 2 (either x or y) : -75275[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +50.4018
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0579869
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 6.17286
Calculated polarisation in cavity : 16.3978
Photodiode 1 after Wollaston prism : 0.0519679
Photodiode 2 after Wollaston prism : 0.0378262
Step size for RHWP scan : 11162
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.000696259
Left Arm Q1 gauss meter : 0.0002513
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.000359404
Left Arm Q2 momentum : -8.98098e-07
Left Arm Q2 gauss meter : 0.0010977
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00212323
Left Arm D1 momentum : 0.00321549
Left Arm D1 NMR : 0.270362
Left Arm Q3 power supply current : -0.000500285
Left Arm Q3 momentum : -9.98662e-07
Left Arm Q3 gauss meter : -0.00012338
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.000821845
Right Arm Q1 gauss meter : -3.55e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 2.21844e-05
Right Arm Q2 momentum : 0.00246752
Right Arm Q2 gauss meter : 0.0005383
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00341007
Right Arm D1 momentum : 0.00471452
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : 4.8572e-05
Right Arm Q3 momentum : 0.00198534
Right Arm Q3 gauss meter : 5.47e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0215756
Current on Unser monitor : 19.1012
Current on Upstream bcm : 0.0310255
Current on Downstream bcm : 0.0121258
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00267902
Tiefenbach Hall A energy : 397.035
Tiefenbach Hall C energy : 7128.6
Delta(E)/E width (MV_AI_DXWID) : 0.690855
MBSY1c Hall A Beam energy : 396.694
MBSY3c Hall C Beam energy : 7157.07
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 98995.4
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 0.2
Raster Y width : 0.2
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.3359
pressure fill bottle H2 : 14.3725
pressure ballast H2 : 24.2481
pressure exhaust H2 : 14.5357
cryogen input temp : 299.8
crogen return flow : 0.143483
JT valve setting : 98.4375
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_1620.log:
Cumulative stats for 11746 events:
Events failing cut conditions:
0 Low_beam 11746
1 Beam_burp 0
2 Evt_seq 0
3 Pair_seq 1
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------