User name apar
Log entry time 00:01:12 on March 4, 2010
Entry number 310615
keyword=End_of_Parity_Run_1651__CODA_Config=CHInj2
************************************************
Run Number: 1651
End of Run Comment:
Run_type=Test,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=Source Studies:: linear array @ -45, analyzer OUT, lina1 check,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=out,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 1651 at Thu Mar 4 00:01:05 EST 2010
CODA Configuration: CHInj2
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 0
-----------------------------------------
Wien angle : -1.3054
Wien BDL : 2149
Wien field : 55.48
Laser attenuation Hall A : 72
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 9000
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.476
Gun2: PC (PITA) NEG : 6.796
Gun3: PC (PITA) POS : 5
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.52259
Pockels Cell Voltage NEG : 2.35165
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 windows
Helicity Pattern Set : Pair
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 windows
Helicity Pattern Read : Pair
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 21mW
Calculated power in cavity : 1.09035
Photodiode on table : 388.833
Laser X position on QPD 1 : -88.7355
Laser Y position on QPD 1 : -81.7031
Laser X position on QPD 2 : 146.205
Laser Y position on QPD 2 : -442.46
QPD 1 sum : -0.00610396
QPD 2 sum : -0.00366241
Position set point for adjustable
mirror 1 (either x or y) : 12838[c]
Position set point for adjustable
mirror 2 (either x or y) : 91920[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2010
Polarisation in cavity : LEFT
Reflection photodiode : 0.0494415
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 9.45797
Calculated polarisation in cavity : 12.2193
Photodiode 1 after Wollaston prism : 0.0474431
Photodiode 2 after Wollaston prism : 0.0371112
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.01
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.000516327
Left Arm Q1 gauss meter : 0.000276
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.00048295
Left Arm Q2 momentum : -1.08275e-06
Left Arm Q2 gauss meter : 0.0010572
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00206247
Left Arm D1 momentum : 0.00314729
Left Arm D1 NMR : 0.270329
Left Arm Q3 power supply current : -0.000522855
Left Arm Q3 momentum : -1.04371e-06
Left Arm Q3 gauss meter : -0.00011619
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.000890774
Right Arm Q1 gauss meter : -3.68e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.000783847
Right Arm Q2 momentum : -1.91585e-06
Right Arm Q2 gauss meter : 0.0005428
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00352303
Right Arm D1 momentum : 0.00470498
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : 0.000205497
Right Arm Q3 momentum : 0.00198366
Right Arm Q3 gauss meter : 5.44e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0217443
Current on Unser monitor : 19.2705
Current on Upstream bcm : 0.0308893
Current on Downstream bcm : 0.0125993
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.000975271
Tiefenbach Hall A energy : 397.035
Tiefenbach Hall C energy : 7128.6
Delta(E)/E width (MV_AI_DXWID) : 0.590604
MBSY1c Hall A Beam energy : 396.694
MBSY3c Hall C Beam energy : 7157.07
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 98995.4
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 0.2
Raster Y width : 0.2
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.5144
pressure fill bottle H2 : 14.5205
pressure ballast H2 : 24.1657
pressure exhaust H2 : 14.6044
cryogen input temp : 299.8
crogen return flow : 0.16218
JT valve setting : 98.584
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_1651.log:
Cumulative stats for 7833 events:
Events failing cut conditions:
0 Low_beam 7833
1 Beam_burp 0
2 Evt_seq 0
3 Pair_seq 0
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------