NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 22:43:50 on March 4, 2010
Entry number 310782
keyword=End_of_Parity_Run_1708__CODA_Config=CHInj2
************************************************
Run Number: 1708
End of Run Comment:
Run_type=Test,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=injector studies:: PC ON, 120Hz, RHWP @2500, PITA scan,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=out,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 1708 at Thu Mar 4 22:43:43 EST 2010
CODA Configuration: CHInj2
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 0
-----------------------------------------
Wien angle (Vertical) : 88.8235
Wien Vertical BDL : 2149
Wien HV Polarity : OFF
Wien electrode Voltage : 55.48
Wien angle (Solenoids) : 90.7455
Wien BDL (First Solenoid) : 876.345
Wien BDL (Second Solenoid) : 876.345
Wien angle (Horizontal) : 0.1584
Wien BDL : -9.48
Wien HV Polarity (Horizontal) : OFF
Wien electrode Voltage (Horizontal) : 0.1
Laser attenuation Hall A : 118
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 2500
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 6.976
Gun2: PC (PITA) NEG : 8.296
Gun3: PC (PITA) POS : 5
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.95971
Pockels Cell Voltage NEG : 2.77167
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Delay Read : 8 windows
Helicity Pattern Read : Quartet
Helicity Frequency : 120.048
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 21mW
Calculated power in cavity : 0.0197968
Photodiode on table : -1.76969
Laser X position on QPD 1 : -147.891
Laser Y position on QPD 1 : -108.937
Laser X position on QPD 2 : 219.292
Laser Y position on QPD 2 : 7.25044e+06
QPD 1 sum : -0.00366241
QPD 2 sum : 0.00244148
Position set point for adjustable
mirror 1 (either x or y) : -8048[c]
Position set point for adjustable
mirror 2 (either x or y) : -74155[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2010
Polarisation in cavity : RIGHT
Reflection photodiode : -10
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : -7.91979
Calculated polarisation in cavity : 362.017
Photodiode 1 after Wollaston prism : 0.00361446
Photodiode 2 after Wollaston prism : -0.00204982
Step size for RHWP scan : 3750
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.01
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.00109993
Left Arm Q1 gauss meter : 0.0002387
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.000228372
Left Arm Q2 momentum : -6.63081e-07
Left Arm Q2 gauss meter : 0.0011193
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.0021697
Left Arm D1 momentum : 0.00320018
Left Arm D1 NMR : 0.270348
Left Arm Q3 power supply current : -0.000477716
Left Arm Q3 momentum : -1.07375e-06
Left Arm Q3 gauss meter : -0.00011688
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.00241251
Right Arm Q1 gauss meter : -5.49e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.000114619
Right Arm Q2 momentum : -2.66329e-07
Right Arm Q2 gauss meter : 0.0005299
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0394206
Right Arm D1 momentum : 0.00501431
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : 5.23083e-05
Right Arm Q3 momentum : 0.00198813
Right Arm Q3 gauss meter : 5.51e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0233898
Current on Unser monitor : 16.7852
Current on Upstream bcm : 0.0341332
Current on Downstream bcm : 0.0126464
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00222011
Tiefenbach Hall A energy : 397.035
Tiefenbach Hall C energy : 7128.6
Delta(E)/E width (MV_AI_DXWID) : 0.184167
MBSY1c Hall A Beam energy : 396.694
MBSY3c Hall C Beam energy : 7157.07
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 98995.4
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 0.2
Raster Y width : 0.2
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.5357
pressure fill bottle H2 : 14.6075
pressure ballast H2 : 24.1138
pressure exhaust H2 : 14.7356
cryogen input temp : 299.8
crogen return flow : 0
JT valve setting : 98.4863
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_1708.log:
Cumulative stats for 93587 events:
Events failing cut conditions:
0 Low_beam 2
1 Beam_burp 1
2 Evt_seq 4
3 Pair_seq 19
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------