End of Run Comment:
Run_type=Production,beam_current=50,beam_energy=1.063,beam_polarization=0,beam_raster=off,comment_text=Intensity feedback studies,dithering_magnet=off,dithering_magnets=,leftarm_p=1.063,leftarm_theta=5,parity_feedback=on,parity_ihwp=in,rightarm_p=1.063,rightarm_theta=5,target_fanspeed=0 Hz,target_type=No Target, Empty
************************************************
End-of-Parity-run EPICS data for Run Number 2411 at Tue Mar 30 06:32:33 EDT 2010
CODA Configuration: Prex
Compton Run Number : 22380
-----------------------------------------
Wien angle (Vertical) : 88.8235
Wien Vertical BDL (Gcm) : 2152.7
Wien HV Polarity : OFF
Wien electrode Voltage : 55.48
Wien angle (Solenoids) : 90.7455
Wien BDL (First Solenoid) (Gcm) : 876.345
Wien BDL (Second Solenoid) (Gcm) : 876.346
Wien angle (Horizontal) : -58.9992
Wien BDL (Gcm) : -1347
Wien HV Polarity (Horizontal) : ON
Wien electrode Voltage (Horizontal) : 37.247
Laser attenuation Hall A : 135
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 2350
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 5.045
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 6.732
Gun2: PC (PITA) NEG : 8.54
Gun3: PC (PITA) POS : 5
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.57143
Pockels Cell Voltage NEG : 2.39316
Helicity Clock Set : Free Clock
Helicity Delay Set : 16 windows
Helicity Pattern Set : Octet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Stable Read : 4067
Helicity Delay Read : 16 windows
Helicity Pattern Read : Octet
Helicity Frequency : 239.981
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 84mW
Calculated power in cavity : 0.00438529
Photodiode on table : 55.5263
Laser X position on QPD 1 : -147.891
Laser Y position on QPD 1 : -108.937
Laser X position on QPD 2 : -438.543
Laser Y position on QPD 2 : 1327.38
QPD 1 sum : -0.00366241
QPD 2 sum : -0.00122085
Position set point for adjustable
mirror 1 (either x or y) : Home (0[c])
Position set point for adjustable
mirror 2 (either x or y) : -1795[c]
Laser minimum temperature (35.8) : 32.201
Laser temperature set point : +47.200
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0421168
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 4.05603
Calculated polarisation in cavity : 72.7892
Photodiode 1 after Wollaston prism : -0.000367832
Photodiode 2 after Wollaston prism : -5.79262e-05
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : COMPTON_LASERT_RAMPDT --- Invalid channel name
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 446.265
Left Arm Q1 momentum : 1.06285
Left Arm Q1 gauss meter : -0.03741
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 463.023
Left Arm Q2 momentum : 1.06289
Left Arm Q2 gauss meter : 0.24293
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 353.836
Left Arm D1 momentum : 1.06303
Left Arm D1 NMR : 0.393549
Left Arm Q3 power supply current : 462.371
Left Arm Q3 momentum : 1.063
Left Arm Q3 gauss meter : -0.233287
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 437.186
Right Arm Q1 momentum : 1.06307
Right Arm Q1 gauss meter : -0.010955
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 463.684
Right Arm Q2 momentum : 1.063
Right Arm Q2 gauss meter : 0.24187
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 364.426
Right Arm D1 momentum : 1.06302
Right Arm D1 NMR : 0.394473
Right Arm Q3 power supply current : 460.684
Right Arm Q3 momentum : 1.06298
Right Arm Q3 gauss meter : 0.20543
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 45.3897
Current on Unser monitor : 69.8604
Current on Upstream bcm : 41.3112
Current on Downstream bcm : 49.4683
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 58.3739
Tiefenbach Hall A energy : 1060.51
Tiefenbach Hall C energy : 5092.66
Delta(E)/E width (MV_AI_DXWID) : 2.57932
MBSY1c Hall A Beam energy : 1061.34
MBSY3c Hall C Beam energy : 5108.41
MBSY1c magnet current (amp) : 43.916
MBSY1c Bdl : 264859
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 0.2
Raster Y width : 0.2
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : -0.0042626
IPM1C12.YPOS : -0.343129
IPM1H04A.XPOS : -0.386891
IPM1H04A.YPOS : 0.874774
IPM1H04B.XPOS : -0.00313807
IPM1H04B.YPOS : 2.10151
Survey X offset bpm4A : 0.24
Survey Y offset bpm4A : 0.36
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : 1
Survey X offset bpm12 : -0.0042626
Survey Y offset bpm12 : -0.343129
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Empty
Encoder position : 13395291
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 14.4869
pressure fill bottle H2 : 14.3908
pressure ballast H2 : 23.949
pressure exhaust H2 : 14.4854
cryogen input temp : 122.6
crogen return flow : 6.25061
JT valve setting : 0.439453
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_2411.log:
Cumulative stats for 200523 events:
Events failing cut conditions:
0 Low_beam 0
1 Beam_burp 2
2 Evt_seq 0
3 Pair_seq 5
4 Startup 1
5 Adcx_DAC_burp 2
--------------------------------------------------