    So I went into the hall and tried to execute the Q1 reset procedure. The ARM and I heard a click, and saw the current readback on the screen was ramping to the setpoint.

    The current readback on the Hall A Tools screen is zero, however, although the momentum setting seemed correct for a while. I am assuming that I turned the Q1 on but there is some problem with the current readback.

    Now the field is jumping around and like it is not able to get a lock or something. I did NOT try step number 3 (going to the key panel) because I thought step number 2 worked. Maybe I am wrong. At this point we are no worse off than if I had just decided to not come in, so I am wondering if we should just do 1 arm production.