keyword=DVCS Trig scalers
run 7696
re-increase inhibit delay by one clock cycle
HRS singles counted 54 counts before T5 started
Perhaps the run inhibit releases from the TS scaler later than
from the DVCS VME
after 1000 events, T5 has 8 more events than Singles-OR
18 event offset after 2000 events
24 events after 2600 events
28 after 2900
32 after 3100