• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name V. Sulkosky

    Log entry time 09:25:35 on February 01, 2011

    Entry number 346017

    keyword=Trigger Bit Pattern Moved to ROC 10

    I moved the cables from the TS on the BigBite weldment from ROC 8 to ROC 10.
    This is more important for BigBite since it has the capability of multiple
    triggers. The trigger latch pattern cables are now connected to
    ROC 10 in Slot 23 channels 0-11 for the prescaled bits and 13-24 for the
    latched bits with the following map:
    # BigBite trigger bit pattern(prescaled)
    bit1       crate      10    23        0
    bit2       crate      10    23        1
    bit3       crate      10    23        2
    bit4       crate      10    23        3
    bit5       crate      10    23        4
    bit6       crate      10    23        5
    bit7       crate      10    23        6
    bit8       crate      10    23        7
    bit9       crate      10    23        8
    bit10      crate      10    23        9
    bit11      crate      10    23       10
    bit12      crate      10    23       11
    
    # BigBite trigger latch pattern
    lbit1       crate      10    23       13
    lbit2       crate      10    23       14
    lbit3       crate      10    23       15
    lbit4       crate      10    23       16
    lbit5       crate      10    23       17
    lbit6       crate      10    23       18
    lbit7       crate      10    23       19
    lbit8       crate      10    23       20
    lbit9       crate      10    23       21
    lbit10      crate      10    23       22
    lbit11      crate      10    23       23
    lbit12      crate      10    23       24
    
    I have tested the evtypebits variable and it appears to be working.

    A copy of this log entry has been emailed to: nmuangma,lselvy,rom