• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name V. Sulkosky

    Log entry time 19:10:32 on February 06, 2011

    Entry number 346095

    Followups:

    keyword=Recabled EDTM for S1 on RHRS

    When I was setting up the EDTM timing between s1 and s2m on the right HRS,
    I found that the cabling was incorrect. Channels 1-6 contained S1-1L
    through S1-6L. Then channels 7 and 8 were skipped, and S1-1R through
    S1-6R were in channels 9-14. One problem is that channels 13-16 do not
    have an EDTM pulser signal output. Also the signal outputs are rotated so
    that channels 1 and 2 are linked, 3 and 4 are linked etc. In this setup,br> the EDTM pulser would never form a trigger in the AND of left and right
    PMTs for S1.

    I assume this has been setup this way since at least APEX ran.

    I recabled the S1 EDTM as follows:

    S1 Channel     EDTM channel    Discriminator Input
    +++++++++++++++++++++++++++++++++++++++++++++++++++++
    S1-1L               1                   1
    S1-1R               2                   9
    S1-2L               3                   2
    S1-2R               4                  10
    S1-3L               5                   3
    S1-3R               6                  11
    S1-4L               7                   4
    S1-4R               8                  12
    S1-5L               9                   5
    S1-5R              10                  13
    S1-6L              11                   6
    S1-6R              12                  14
    

    This discriminator mapping preserves the left AND right combinations for S1.
    I am fairly confident that the S1 EDTM is also miscabled on the left HRS.


    A copy of this log entry has been emailed to: rom,danez,yez