Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name V. Sulkosky
Log entry time 19:10:32 on February 06, 2011
Entry number 346095
Followups:
keyword=Recabled EDTM for S1 on RHRS
When I was setting up the EDTM timing between s1 and s2m on the right
HRS,
I found that the cabling was incorrect. Channels 1-6 contained S1-1L
through S1-6L. Then channels 7 and 8 were skipped, and S1-1R through
S1-6R were in channels 9-14. One problem is that channels 13-16 do not
have an EDTM pulser signal output. Also the signal outputs are rotated
so
that channels 1 and 2 are linked, 3 and 4 are linked etc. In this setup,br>
the EDTM pulser would never form a trigger in the AND of left and right
PMTs for S1.
I assume this has been setup this way since at least APEX ran.
I recabled the S1 EDTM as follows:
S1 Channel EDTM channel Discriminator Input
+++++++++++++++++++++++++++++++++++++++++++++++++++++
S1-1L 1 1
S1-1R 2 9
S1-2L 3 2
S1-2R 4 10
S1-3L 5 3
S1-3R 6 11
S1-4L 7 4
S1-4R 8 12
S1-5L 9 5
S1-5R 10 13
S1-6L 11 6
S1-6R 12 14
This discriminator mapping preserves the left AND right combinations for
S1.
I am fairly confident that the S1 EDTM is also miscabled on the
left HRS.
A copy of this log entry has been emailed to: rom,danez,yez