Right HRS: The right HRS cannot be retimed at this time, as the L1A signal arrives approximately 150ns after the strobe/retiming signal, completely missing the ADC signal from the scintillators. This is due to the use of RG58 cables; this problem should be easily resolved once the new RG8s are connected.
Left HRS: The LDU 1200 delay modules and the extra delay ribbon cables have been removed from the electronics. The S1 and S2m TDC signals were moved to the 1877 card in slot 23. The DB files has been updated.
The L1A coming in was put through a delay module and delayed an additional 72ns to properly coincide (with a buffer of ~70ns) with the strobe.
Unfortunately, there are no gates going into ROC3 and ROC4. While CODA says it's getting events, there are no gates. The current theory is that the transition module has not been properly connected for this setup; this theory will be tested in the morning, unless someone more experienced already knows what the problem is.