• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name saw

    Log entry time 16:58:07 on February 09, 2011

    Entry number 346228

    keyword=F1 TDC mapping

    There are two F1s installed. The E counters are connected to the TDC in slot 15, and the dE counters in slot 17. The channel numbers on F1s are non-conventional. The top right connector is channels 0,2,4,...30, the top left connector is channels 1,3,5,...,31, the bottom right connector is 32, 34, ..., 62, and the bottom left is 33, 35, ..., 63. I have heard, but don't know for sure, the the Hall A analylzer class for the F1s renumbers these channels as 0-15, 16-31, 32-47, 48-63. Given this, the following is the map:
    Slot   Connector     Signals
    
    15     Top Right     E1-16L
    15     Top Left      E1-16R
    15     Bottom Right  E17-24L, E17-24R
    15     Bottom Left   Reference time in first channel of connector
    17     Top Right     DE1-16L
    17     Top Left      DE1-16R
    17     Bottom Right  DE17-24L, DE17-24R
    17     Bottom Left   Not used
    


    A copy of this log entry has been emailed to: lselvy@jlab.org