keyword=F1 TDC mapping
There are two F1s installed. The E counters are connected to the TDC in
slot 15, and the dE counters in slot 17. The channel numbers on F1s are
non-conventional. The top right connector is channels 0,2,4,...30, the
top left connector is channels 1,3,5,...,31, the bottom right connector
is 32, 34, ..., 62, and the bottom left is 33, 35, ..., 63. I have
heard, but don't know for sure, the the Hall A analylzer class for the
F1s renumbers these channels as 0-15, 16-31, 32-47, 48-63. Given this,
the following is the map:
Slot Connector Signals
15 Top Right E1-16L
15 Top Left E1-16R
15 Bottom Right E17-24L, E17-24R
15 Bottom Left Reference time in first channel of connector
17 Top Right DE1-16L
17 Top Left DE1-16R
17 Bottom Right DE17-24L, DE17-24R
17 Bottom Left Not used