    keyword=Delayed T7 (HAND) and Checked T6

    In an attempt to bring the HAND singles trigger in better alignment with HRS triggers particularly T3, I have delayed T7 before going into the trigger supervisor by about 120 ns. It now comes about 50 ns after T3, which might be a bit longer than preferred.

    I also checked the timing between T6 and T3, the T6 trigger does come after T3 at the TS. However I can only check this with the EDTM trigger setup. It is not completely guaranteed that is true for real events.