Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name V. Sulkosky
Log entry time 18:49:40 on February 17, 2011
Entry number 347377
This entry is a followup to: 347236
keyword=Trigger Arrival at Trigger Supervisor
At the trigger supervisor trigger input the coincidence trigger T5 comes:
before T1 by about 10 ns
before T2 by about 22 ns
before T3 by about 23 ns
before T4 by about 27 ns
before T6 by about 36 ns
before T7 by about 72 ns
I thought about removing delay to T7, but we probably do not care about T7
especially for the next five days. The timing for T2 and T4 were
determined by taking the MLU output for T1 and T3, respectively,
otherwise I cannot see T2 and T4 wrt other triggers.
A copy of this log entry has been emailed to: danez,yez,rom,kelleher