NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 01:55:17 on December 15, 2011
Entry number 359934
keyword=Start_Run_20888,Run_type=Commission,target_type=empty,beam_e0=1.72,beam_fraster=on,beam_sraster=off,beam_current=0,rightarm_p=1.72,rightarm_theta=5.69,rightarm_sieve=out,septum_current=489,comment_text=
Run Timestamp: Thu Dec 15 01:54:33 EST 2011
Beginning-of-run EPICS data for Run Number 20888 at Thu Dec 15 01:55:11 EST 2011
Run_type=Commission
target_type=empty
beam_e0=1.72
beam_fraster=on
beam_sraster=off
beam_current=0
rightarm_p=1.72
rightarm_theta=5.69
rightarm_sieve=out
septum_current=489
comment_text=
;This file is automatically generated from Prescales GUI.
;To generate this file, type "prescaleL" without quotes on a-onl@adaql2
;terminal then input the desired prescales and Save.
;T1 = R-arm scint trig (s1.AND.s2m)
;T2 = R-arm efficiency trigger
;T8 = 1024 Hz pulser or whatever
ps1=3,ps2=1,ps3=0,ps4=0,ps5=0,ps6=0,ps7=0,ps8=0
Left Arm Q1 momentum : 0.00236415
Left Arm Q1 power supply : 0
Left Arm Q1 gauss meter : 0.0001444
Left Arm Q2 power supply current : 0
Left Arm Q2 momentum : 0.00418562
Left Arm Q2 gauss meter : 0.0011258
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 0
Left Arm D1 momentum : 0.00340617
Left Arm D1 NMR : 0.315144
Left Arm Q3 power supply current : 0
Left Arm Q3 momentum : 0.00448499
Left Arm Q3 gauss meter : -0.0001561
Left Arm Q3 power supply polarity : enabled
Left Arm B Field Hall Probe (D-G) : -0.0012236
-----
Right Arm Q1 momentum : 1.57006
Right Arm Q1 power supply : 859.739
Right Arm Q1 gauss meter : -0.021537
Right Arm Q2 power supply current : 748.313
Right Arm Q2 momentum : 1.71648
Right Arm Q2 gauss meter : 0.3686
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 593.582
Right Arm D1 momentum : 1.71999
Right Arm D1 NMR : 0.638266
Right Arm Q3 power supply current : 825.395
Right Arm Q3 momentum : 1.53003
Right Arm Q3 gauss meter : 0.3908
Right Arm Q3 power supply polarity : disabled
Right Arm B Field Hall Probe (D-G) : -0.6296
-----
Left Arm Top VDC Current : -0.976562
Left Arm Bottom VDC Current : -21.4355
Left Arm Top VDC voltage : 4.00391
Left Arm Bottom VDC voltage : 3.99707
-----
Right Arm Top VDC Current : -1.5625
Right Arm Bottom VDC Current : 0.78125
Right Arm Top VDC voltage : 3.99658
Right Arm Bottom VDC voltage : 3.99756
-----
HacL_HPE1313A:0_Ch58 : -0.299316
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : -0.0200195
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----
Right Arm D1 momentum : 1.71999
Right Arm arm angle : 12.501
-----
Left VDC -DISC LVL Top : 3.90723
Left VDC -DISC LVL Bottom : 3.96289
Left VDC -DISC LVL Voltage1 : 4.96924
Left VDC -DISC LVL Voltage2 : -5.06201
Left VDC -DISC LVL Top Set : 4
Left VDC -DISC LVL Bottom Set : 4
-----
Right Arm Arm Collimator : 0.0612305
HacR_HPE1313A:0_Ch58 : -0.695801
HacR_HPE1313A:0_Ch55 : 22.3145
HacR_HPE1313A:0_Ch54 : -1.02441
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.501
-----
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H05A.XPOS : 0
IPM1H05A.YPOS : 0
IPM1H05B.XPOS : 0
IPM1H05B.YPOS : 0
Survey X offset bpmA : 0
Survey Y offset bpmA : 0
Survey X offset bpmB : 0
Survey Y offset bpmB : 0
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2626.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : -92.0371
Wien BDL (First Solenoid) (Gcm) : -1021.5
Wien BDL (Second Solenoid) (Gcm) : -1021.5
Wien angle (Horizontal) : 0
Wien BDL (Gcm) : -25
Wien HV Polarity (Horizontal) : POSITIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 180
Laser power Hall A : 0
Half-wave plate (off=out) : OUT
rotating waveplate : 349
Beam Half-wave plate (off=out) : OUT
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Right septum current : 488.959
Left septum current : 489.373
Target In : enabled
Target Out : disabled
Helium Pressure : disabled