NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 04:49:40 on December 16, 2011
Entry number 360083
keyword=Start_Run_1749,Run_type=Commission,target_type=Carbon,beam_e0=1.7,beam_fraster=off,beam_sraster=off,beam_current=0,leftarm_p=1.7,leftarm_theta=12.5,leftarm_sieve=out,septum_current=460,comment_text=bpm check, bpm check 0 0 on 1H05B
Beginning-of-run EPICS data for Run Number 1749 at Fri Dec 16 04:49:35 EST 2011
Run_type=Commission
target_type=Carbon
beam_e0=1.7
beam_fraster=off
beam_sraster=off
beam_current=0
leftarm_p=1.7
leftarm_theta=12.5
leftarm_sieve=out
septum_current=460
comment_text=bpm check, bpm check 0 0 on 1H05B
;This file is automatically generated from Prescales GUI.
;To generate this file, type "prescaleL" without quotes on a-onl@adaql2
;terminal then input the desired prescales and Save.
;T3 = L-arm scint trig (s1.AND.s2m)
;T4 = L-arm efficiency trigger
;T8 = 1024 Hz pulser or whatever
ps1=0,ps2=0,ps3=1,ps4=1,ps5=0,ps6=0,ps7=0,ps8=0
Left Arm Q1 momentum : 1.13332
Left Arm Q1 power supply : 852.636
Left Arm Q1 gauss meter : -0.07085
Left Arm Q2 power supply current : 702.775
Left Arm Q2 momentum : 1.63208
Left Arm Q2 gauss meter : 0.3711
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 582.573
Left Arm D1 momentum : 1.73721
Left Arm D1 NMR : 0.642887
Left Arm Q3 power supply current : 691.009
Left Arm Q3 momentum : 1.73568
Left Arm Q3 gauss meter : -0.34796
Left Arm Q3 power supply polarity : disabled
Left Arm B Field Hall Probe (D-G) : -0.6185
-----
Right Arm Q1 momentum : 1.42025
Right Arm Q1 power supply : 777.707
Right Arm Q1 gauss meter : -0.019492
Right Arm Q2 power supply current : 634.414
Right Arm Q2 momentum : 1.45522
Right Arm Q2 gauss meter : 0.3334
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 534.382
Right Arm D1 momentum : 1.55598
Right Arm D1 NMR : 0.577404
Right Arm Q3 power supply current : 746.722
Right Arm Q3 momentum : 1.38419
Right Arm Q3 gauss meter : 0.3314
Right Arm Q3 power supply polarity : disabled
Right Arm B Field Hall Probe (D-G) : -0.5695
-----
Left Arm Top VDC Current : -1.41602
Left Arm Bottom VDC Current : 28.7598
Left Arm Top VDC voltage : 4.00781
Left Arm Bottom VDC voltage : 3.99561
-----
Right Arm Top VDC Current : -1.95312
Right Arm Bottom VDC Current : -3.36914
Right Arm Top VDC voltage : 4.01855
Right Arm Bottom VDC voltage : 3.97412
-----
HacL_HPE1313A:0_Ch58 : -0.299316
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : -0.0219727
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----
Right Arm D1 momentum : 1.55598
Right Arm arm angle : 12.501
-----
Left VDC -DISC LVL Top : 3.90771
Left VDC -DISC LVL Bottom : 3.96436
Left VDC -DISC LVL Voltage1 : 4.97021
Left VDC -DISC LVL Voltage2 : -5.06104
Left VDC -DISC LVL Top Set : 4
Left VDC -DISC LVL Bottom Set : 4
-----
HacR_HPE1313A:0_Ch58 : -0.697266
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -1.02588
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.501
-----
IPM1C12.XPOS : 0.0483477
IPM1C12.YPOS : 0.808537
IPM1H05A.XPOS : -0.323272
IPM1H05A.YPOS : 0.075343
IPM1H05B.XPOS : -0.0183922
IPM1H05B.YPOS : -0.0582249
Survey X offset bpmA : 0
Survey Y offset bpmA : 0
Survey X offset bpmB : 0
Survey Y offset bpmB : 0
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2626.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : -92.0371
Wien BDL (First Solenoid) (Gcm) : -1021.5
Wien BDL (Second Solenoid) (Gcm) : -1021.5
Wien angle (Horizontal) : 0
Wien BDL (Gcm) : -25
Wien HV Polarity (Horizontal) : POSITIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 152
Laser power Hall A : 0
Half-wave plate (off=out) : IN
rotating waveplate : 6478
Beam Half-wave plate (off=out) : IN
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Right septum current : 459.943
Left septum current : 460.347
Target In : disabled
Target Out : enabled
Helium Pressure : disabled