NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 05:31:48 on December 16, 2011
Entry number 360097
keyword=End_of_Run_1754
****************************
Run Number: 1754
End of Run Comment:
Run_type=Commission,target_type=Carbon,beam_e0=1.7,beam_fraster=off,beam_sraster=off,beam_current=0,leftarm_p=1.7,leftarm_theta=12.5,leftarm_sieve=out,septum_current=460,comment_text=bpm check, bpm check 0 0 on 1H05B
PRESCALE FACTORS:ps1=0 ps2=0 ps3=2 ps4=1 ps5=0 ps6=0 ps7=0 ps8=0
EVENTS : [0]: 716789 [+]: 252031 [-]: 247913
TIME : [0]: 4.439 mins [+]: 1.656 mins [-]: 1.661 mins
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 11.97% [+]: 10.05% [-]: 9.94%
TRIGGER RATES: PRES/REAL
T1[0] :T1: 0.0/11252.3 Hz T2[0] :T2: 0.0/87.9 Hz T3[0] :T3:2996.7/5993.4 Hz T4[0] :T4:60.7/60.7 Hz T5[0] :T5: 0.0/0.0 Hz T6[0] :T6: 0.0/9740.1 Hz T7[0] :T7: 0.0/103847.9 Hz T8[0] :T8: 0.0/1024.0 Hz
T1[+] :T1: 0.0/10326.5 Hz T2[+] :T2: 0.0/89.4 Hz T3[+] :T3:2755.1/5510.1 Hz T4[+] :T4:64.7/64.7 Hz T5[+] :T5: 0.0/15.4 Hz T6[+] :T6: 0.0/9217.9 Hz T7[+] :T7: 0.0/102675.6 Hz T8[+] :T8: 0.0/1024.0 Hz
T1[-] :T1: 0.0/178453.9 Hz T2[-] :T2: 0.0/168399.8 Hz T3[-] :T3:2704.5/5409.0 Hz T4[-] :T4:57.2/57.2 Hz T5[-] :T5: 0.0/14.3 Hz T6[-] :T6: 0.0/9108.1 Hz T7[-] :T7: 0.0/102367.3 Hz T8[-] :T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] :T1: 0/2997005 T2[0] :T2: 0/23401 T3[0] :T3: 798164/1596329 T4[0] :T4: 16155/16155 T5[0] :T5: 0/0 T6[0] :T6: 0/2594232 T7[0] :T7: 0/27659431 T8[0] :T8: 0/272738
T1[+] :T1: 0/1026111 T2[+] :T2: 0/8884 T3[+] :T3: 273764/547528 T4[+] :T4: 6433/6433 T5[+] :T5: 0/1531 T6[+] :T6: 0/915960 T7[+] :T7: 0/10202587 T8[+] :T8: 0/101752
T1[-] :T1: 0/17787536 T2[-] :T2: 0/16785385 T3[-] :T3: 269573/539146 T4[-] :T4: 5703/5703 T5[-] :T5: 0/1421 T6[-] :T6: 0/907859 T7[-] :T7: 0/10203543 T8[-] :T8: 0/102068
AVERAGE CURRENT
BCM x1 : -0.2153uA BCM x3 : 47.5612uA BCM x10: 11.2664uA
Test of Helicity gates
Time diff of helicity to nonhelicity times = 53.38963 seconds
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :1.007E+06 ppm BCM u3 : 7984 ppm BCM u10: 2771 ppm
BCM d1 : 1552 ppm BCM d3 : 1556 ppm BCM d10:1.008E+06 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0] : -8.123E-05 BCM u3 [0] : 0.02536 BCM u10[0] : 0.006009
BCM u1 [+] : 0.008117 BCM u3 [+] : 0.01131 BCM u10[+] : 0.002944
BCM u1 [-] : -3.015E-05 BCM u3 [-] : 0.01116 BCM u10[-] : 0.002937
BCM d1 [0] : -3.345E-05 BCM d3 [0] : -2.222E-05 BCM d10[0] : -7.559E-06
BCM d1 [+] : 0.01358 BCM d3 [+] : 0.002189 BCM d10[+] : 0.0006903
BCM d1 [-] : 0.01358 BCM d3 [-] : 0.002189 BCM d10[-] : -2.797E-06
****************************
End-of-run EPICS data for Run Number 1754 at Fri Dec 16 05:31:45 EST 2011
Left Arm Top VDC Current : -0.585938
Left Arm Bottom VDC Current : -16.4551
Left Arm Top VDC voltage : 4.00488
Left Arm Bottom VDC voltage : 3.99707
-----
Right Arm Top VDC Current : -3.32031
Right Arm Bottom VDC Current : -3.56445
Right Arm Top VDC voltage : 4.01611
Right Arm Bottom VDC voltage : 3.97412
-----
Left Arm Q1 momentum : 1.13332
Left Arm Q1 power supply : 852.636
Left Arm Q1 gauss meter : -0.07084
Left Arm Q2 gauss meter : 0.3711
Left Arm Q2 power supply current : 702.779
Left Arm Q2 momentum : 1.63209
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 582.564
Left Arm D1 momentum : 1.73721
Left Arm D1 NMR : 0.642886
Left Arm arm angle : -0.179
Left Arm Q3 gauss meter : -0.34793
Left Arm Q3 power supply current : 691.006
Left Arm Q3 momentum : 1.73568
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.42035
Right Arm Q1 power supply : 777.76
Right Arm Q1 gauss meter : -0.019514
Right Arm Q2 power supply current : 634.415
Right Arm Q2 momentum : 1.45522
Right Arm Q2 gauss meter : 0.3334
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 534.382
Right Arm D1 momentum : 1.55598
Right Arm D1 NMR : 0.577405
Right Arm arm angle : 12.501
Right Arm Q3 power supply current : 746.722
Right Arm Q3 momentum : 1.38419
Right Arm Q3 gauss meter : 0.3314
Right Arm Q3 power supply polarity : disabled
-----
HacL_HPE1313A:0_Ch58 : -0.29834
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.0214844
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Left VDC -DISC LVL Top : 3.90723
Left VDC -DISC LVL Bottom : 3.96338
Left VDC -DISC LVL Voltage1 : 4.97021
Left VDC -DISC LVL Voltage2 : -5.06006
-----
Right Arm Collimator : 0.0570313
HacR_HPE1313A:0_Ch58 : -0.697754
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -1.02539
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.501