NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 13:09:52 on December 16, 2011
Entry number 360189
keyword=End_of_Run_20944
****************************
Run Number: 20944
End of Run Comment:
Run_type=Commission,target_type=Carbon,beam_e0=1.72,beam_fraster=off,beam_sraster=off,beam_current=0.15,rightarm_p=1.556,rightarm_theta=5.69,rightarm_sieve=out,septum_current=460,comment_text=Carbon elastic, bpm check 0 0 on 1H05B, BCM gain A 26/26/5 B 24/25/4
PRESCALE FACTORS:ps1=3 ps2=1 ps3=0 ps4=0 ps5=0 ps6=0 ps7=0 ps8=0
EVENTS : [0]: 85876 [+]: 40605 [-]: 39990
TIME : [0]: 0.940 mins [+]: 0.466 mins [-]: 0.466 mins
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 2.17% [+]: 7.77% [-]: 8.20%
TRIGGER RATES: PRES/REAL
T1[0] :T1:1523.8/4571.2 Hz T2[0] :T2:32.5/32.5 Hz T3[0] :T3: 0.0/1854.2 Hz T4[0] :T4: 0.0/15.6 Hz T5[0] :T5: 0.0/6720.9 Hz T6[0] :T6: 0.0/7000.4 Hz T7[0] :T7: 0.0/0.0 Hz T8[0] :T8: 0.0/1024.0 Hz
T1[+] :T1:1541.1/4623.4 Hz T2[+] :T2:33.0/33.0 Hz T3[+] :T3: 0.0/1868.1 Hz T4[+] :T4: 0.0/15.4 Hz T5[+] :T5: 0.0/6785.5 Hz T6[+] :T6: 0.0/7007.4 Hz T7[+] :T7: 0.0/0.0 Hz T8[+] :T8: 0.0/1024.0 Hz
T1[-] :T1:1524.9/4574.9 Hz T2[-] :T2:32.9/32.9 Hz T3[-] :T3: 0.0/1869.3 Hz T4[-] :T4: 0.0/15.9 Hz T5[-] :T5: 0.0/6723.3 Hz T6[-] :T6: 0.0/7059.9 Hz T7[-] :T7: 0.0/0.0 Hz T8[-] :T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] :T1: 85952/257856 T2[0] :T2: 1836/1836 T3[0] :T3: 0/104594 T4[0] :T4: 0/881 T5[0] :T5: 0/379115 T6[0] :T6: 0/394879 T7[0] :T7: 0/0 T8[0] :T8: 0/57762
T1[+] :T1: 43105/129315 T2[+] :T2: 922/922 T3[+] :T3: 0/52251 T4[+] :T4: 0/431 T5[+] :T5: 0/189789 T6[+] :T6: 0/195996 T7[+] :T7: 0/0 T8[+] :T8: 0/28641
T1[-] :T1: 42643/127931 T2[-] :T2: 919/919 T3[-] :T3: 0/52274 T4[-] :T4: 0/444 T5[-] :T5: 0/188010 T6[-] :T6: 0/197421 T7[-] :T7: 0/0 T8[-] :T8: 0/28635
AVERAGE CURRENT
BCM x1 : -0.2153uA BCM x3 : 8.0350 uA BCM x10: 13.9296uA
Test of Helicity gates
Time diff of helicity to nonhelicity times = -3.43515 seconds
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 1E+39 ppm BCM u3 : -21.06 ppm BCM u10: -719.2 ppm
BCM d1 : 1E+39 ppm BCM d3 : 1E+39 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0] : -1.72E-05 BCM u3 [0] : 0.0009112 BCM u10[0] : 0.001573
BCM u1 [+] : -8.53E-06 BCM u3 [+] : 0.0004523 BCM u10[+] : 0.0007794
BCM u1 [-] : -8.528E-06 BCM u3 [-] : 0.0004522 BCM u10[-] : 0.0007804
BCM d1 [0] : -7.084E-06 BCM d3 [0] : -4.706E-06 BCM d10[0] : -1.601E-06
BCM d1 [+] : -3.513E-06 BCM d3 [+] : -2.334E-06 BCM d10[+] : -7.938E-07
BCM d1 [-] : -3.512E-06 BCM d3 [-] : -2.333E-06 BCM d10[-] : -7.936E-07
****************************
End-of-run EPICS data for Run Number 20944 at Fri Dec 16 13:09:50 EST 2011
Left Arm Top VDC Current : 3.51562
Left Arm Bottom VDC Current : 4.24805
Left Arm Top VDC voltage : 4.00439
Left Arm Bottom VDC voltage : 3.99902
-----
Right Arm Top VDC Current : -3.32031
Right Arm Bottom VDC Current : -1.85547
Right Arm Top VDC voltage : 4.01611
Right Arm Bottom VDC voltage : 3.97363
-----
Left Arm Q1 momentum : 1.13332
Left Arm Q1 power supply : 852.689
Left Arm Q1 gauss meter : -0.07082
Left Arm Q2 gauss meter : 0.3711
Left Arm Q2 power supply current : 702.778
Left Arm Q2 momentum : 1.63209
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 582.555
Left Arm D1 momentum : 1.7372
Left Arm D1 NMR : 0.642883
Left Arm arm angle : -0.179
Left Arm Q3 gauss meter : -0.34792
Left Arm Q3 power supply current : 691.01
Left Arm Q3 momentum : 1.73569
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.57006
Right Arm Q1 power supply : 859.739
Right Arm Q1 gauss meter : -0.021507
Right Arm Q2 power supply current : 701.294
Right Arm Q2 momentum : 1.60863
Right Arm Q2 gauss meter : 0.3686
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 534.383
Right Arm D1 momentum : 1.55598
Right Arm D1 NMR : 0.577405
Right Arm arm angle : 12.501
Right Arm Q3 power supply current : 825.395
Right Arm Q3 momentum : 1.53003
Right Arm Q3 gauss meter : 0.3666
Right Arm Q3 power supply polarity : disabled
-----
HacL_HPE1313A:0_Ch58 : -0.297363
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.0214844
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Left VDC -DISC LVL Top : 3.90527
Left VDC -DISC LVL Bottom : 3.96094
Left VDC -DISC LVL Voltage1 : 4.96729
Left VDC -DISC LVL Voltage2 : -5.06201
-----
Right Arm Collimator : 0.061084
HacR_HPE1313A:0_Ch58 : -0.697266
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -1.0249
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.501