Log entry time 22:34:30 on December 17, 2011
Entry number 360592
keyword=End_of_Run_21018
****************************
Run Number: 21018
End of Run Comment:
Run_type=Commission,target_type=Carbon,beam_e0=1.72,beam_fraster=on,beam_sraster=off,beam_current=1,rightarm_p=1.317,rightarm_theta=5.69,rightarm_sieve=out,septum_current=372,comment_text=config A
PRESCALE FACTORS:ps1=2 ps2=1 ps3=0 ps4=0 ps5=0 ps6=0 ps7=0 ps8=0
EVENTS : [0]: 3491939 [+]: 1631062 [-]: 1628525
TIME : [0]: 17.110 mins [+]: 7.998 mins [-]: 7.997 mins
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 10.55% [+]: 10.55% [-]: 10.55%
TRIGGER RATES: PRES/REAL
T1[0] :T1:3752.9/7505.9 Hz T2[0] :T2:49.9/49.9 Hz T3[0] :T3: 0.0/2563.7 Hz T4[0] :T4: 0.0/22.2 Hz T5[0] :T5: 0.0/10575.6 Hz T6[0] :T6: 0.0/12362.4 Hz T7[0] :T7: 0.0/0.0 Hz T8[0] :T8: 0.0/1024.0 Hz
T1[+] :T1:3750.2/7500.4 Hz T2[+] :T2:49.9/49.9 Hz T3[+] :T3: 0.0/2560.3 Hz T4[+] :T4: 0.0/22.1 Hz T5[+] :T5: 0.0/10564.2 Hz T6[+] :T6: 0.0/12367.9 Hz T7[+] :T7: 0.0/0.0 Hz T8[+] :T8: 0.0/1024.0 Hz
T1[-] :T1:3744.6/7489.2 Hz T2[-] :T2:49.8/49.8 Hz T3[-] :T3: 0.0/2559.8 Hz T4[-] :T4: 0.0/22.2 Hz T5[-] :T5: 0.0/10558.1 Hz T6[-] :T6: 0.0/12318.0 Hz T7[-] :T7: 0.0/0.0 Hz T8[-] :T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] :T1:3852798/7705596 T2[0] :T2: 51256/51256 T3[0] :T3: 0/2631863 T4[0] :T4: 0/22784 T5[0] :T5: 0/10856980 T6[0] :T6: 0/12691306 T7[0] :T7: 0/0 T8[0] :T8: 0/1051245
T1[+] :T1:1799554/3599108 T2[+] :T2: 23928/23928 T3[+] :T3: 0/1228559 T4[+] :T4: 0/10626 T5[+] :T5: 0/5069287 T6[+] :T6: 0/5934797 T7[+] :T7: 0/0 T8[+] :T8: 0/491372
T1[-] :T1:1796836/3593673 T2[-] :T2: 23898/23898 T3[-] :T3: 0/1228291 T4[-] :T4: 0/10641 T5[-] :T5: 0/5066264 T6[-] :T6: 0/5910753 T7[-] :T7: 0/0 T8[-] :T8: 0/491363
AVERAGE CURRENT
BCM x1 : -0.2153uA BCM x3 : 53.7012uA BCM x10: 42.1761uA
Test of Helicity gates
Time diff of helicity to nonhelicity times = -0.17893 seconds
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 1E+39 ppm BCM u3 : -3.309 ppm BCM u10: -0.3206 ppm
BCM d1 : 1E+39 ppm BCM d3 : 1E+39 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0] : -0.0003131 BCM u3 [0] : 0.1103 BCM u10[0] : 0.08663
BCM u1 [+] : -0.0001463 BCM u3 [+] : 0.05148 BCM u10[+] : 0.04041
BCM u1 [-] : -0.0001463 BCM u3 [-] : 0.05148 BCM u10[-] : 0.04041
BCM d1 [0] : -0.0001289 BCM d3 [0] : -8.565E-05 BCM d10[0] : -2.914E-05
BCM d1 [+] : -6.026E-05 BCM d3 [+] : -4.004E-05 BCM d10[+] : -1.362E-05
BCM d1 [-] : -6.026E-05 BCM d3 [-] : -4.003E-05 BCM d10[-] : -1.362E-05
****************************
End-of-run EPICS data for Run Number 21018 at Sat Dec 17 22:34:28 EST 2011
Left Arm Top VDC Current : -0.634766
Left Arm Bottom VDC Current : -12.4023
Left Arm Top VDC voltage : 4.00342
Left Arm Bottom VDC voltage : 3.99756
-----
Right Arm Top VDC Current : -0.292969
Right Arm Bottom VDC Current : -3.51562
Right Arm Top VDC voltage : 4.0166
Right Arm Bottom VDC voltage : 3.97363
-----
Left Arm Q1 momentum : 0.867545
Left Arm Q1 power supply : 652.682
Left Arm Q1 gauss meter : -0.05431
Left Arm Q2 gauss meter : 0.2837
Left Arm Q2 power supply current : 535.342
Left Arm Q2 momentum : 1.24324
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 437.571
Left Arm D1 momentum : 1.31698
Left Arm D1 NMR : 0.48748
Left Arm arm angle : -0.179
Left Arm Q3 gauss meter : -0.31995
Left Arm Q3 power supply current : 633.741
Left Arm Q3 momentum : 1.59184
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.30624
Right Arm Q1 power supply : 715.274
Right Arm Q1 gauss meter : -0.017943
Right Arm Q2 power supply current : 583.437
Right Arm Q2 momentum : 1.33829
Right Arm Q2 gauss meter : 0.3066
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 450.786
Right Arm D1 momentum : 1.31704
Right Arm D1 NMR : 0.488736
Right Arm arm angle : 12.501
Right Arm Q3 power supply current : 686.761
Right Arm Q3 momentum : 1.27304
Right Arm Q3 gauss meter : 0.305
Right Arm Q3 power supply polarity : disabled
-----
HacL_HPE1313A:0_Ch58 : -0.29834
HacL_HPE1313A:0_Ch55 : 23.291
HacL_HPE1313A:0_Ch54 : -0.0205078
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Left VDC -DISC LVL Top : 3.90527
Left VDC -DISC LVL Bottom : 3.96094
Left VDC -DISC LVL Voltage1 : 4.96826
Left VDC -DISC LVL Voltage2 : -5.06201
-----
Right Arm Collimator : 0.0553711
HacR_HPE1313A:0_Ch58 : -0.696777
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -1.02588
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.501