NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 00:53:33 on December 18, 2011
Entry number 360620
keyword=End_of_Run_1902
****************************
Run Number: 1902
End of Run Comment:
Run_type=Commission,target_type=empty,beam_e0=1.72,beam_fraster=on,beam_sraster=off,beam_current=1,leftarm_p=1.317,leftarm_theta=5.69,leftarm_sieve=out,septum_current=372,comment_text=config D Test T8 and buffering
PRESCALE FACTORS:ps1=0 ps2=0 ps3=1 ps4=1 ps5=0 ps6=0 ps7=0 ps8=0
EVENTS : [0]: 2652 [+]: 1163 [-]: 1170
TIME : [0]: 2.326 mins [+]: 1.055 mins [-]: 1.060 mins
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 0.55% [+]: 2.18% [-]: 3.46%
TRIGGER RATES: PRES/REAL
T1[0] :T1: 0.0/14.3 Hz T2[0] :T2: 0.0/2.7 Hz T3[0] :T3:15.0/15.0 Hz T4[0] :T4: 4.1/4.1 Hz T5[0] :T5: 0.0/0.0 Hz T6[0] :T6: 0.0/3552.1 Hz T7[0] :T7: 0.0/103844.9 Hz T8[0] :T8: 0.0/1024.0 Hz
T1[+] :T1: 0.0/13.8 Hz T2[+] :T2: 0.0/3.0 Hz T3[+] :T3:14.7/14.7 Hz T4[+] :T4: 4.0/4.0 Hz T5[+] :T5: 0.0/0.0 Hz T6[+] :T6: 0.0/3550.0 Hz T7[+] :T7: 0.0/103850.7 Hz T8[+] :T8: 0.0/1024.0 Hz
T1[-] :T1: 0.0/263764.8 Hz T2[-] :T2: 0.0/2.5 Hz T3[-] :T3:15.0/15.0 Hz T4[-] :T4: 4.1/4.1 Hz T5[-] :T5: 0.0/3.2 Hz T6[-] :T6: 0.0/3538.2 Hz T7[-] :T7: 0.0/103358.1 Hz T8[-] :T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] :T1: 0/2001 T2[0] :T2: 0/383 T3[0] :T3: 2093/2093 T4[0] :T4: 574/574 T5[0] :T5: 0/0 T6[0] :T6: 0/495765 T7[0] :T7: 0/14493561 T8[0] :T8: 0/142919
T1[+] :T1: 0/876 T2[+] :T2: 0/192 T3[+] :T3: 933/933 T4[+] :T4: 256/256 T5[+] :T5: 0/0 T6[+] :T6: 0/224751 T7[+] :T7: 0/6574741 T8[+] :T8: 0/64829
T1[-] :T1: 0/16778174 T2[-] :T2: 0/157 T3[-] :T3: 953/953 T4[-] :T4: 259/259 T5[-] :T5: 0/202 T6[-] :T6: 0/225068 T7[-] :T7: 0/6574643 T8[-] :T8: 0/65137
AVERAGE CURRENT
BCM x1 : 2.3669 uA BCM x3 : -0.0621uA BCM x10: -0.0304uA
Test of Helicity gates
Time diff of helicity to nonhelicity times = 3.77772 seconds
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 2878 ppm BCM u3 : 1E+39 ppm BCM u10: 1E+39 ppm
BCM d1 : 2476 ppm BCM d3 : 1E+39 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0] : 0.0002181 BCM u3 [0] : -5.683E-06 BCM u10[0] : -4.522E-06
BCM u1 [+] : 9.885E-05 BCM u3 [+] : -2.578E-06 BCM u10[+] : -2.051E-06
BCM u1 [-] : 9.874E-05 BCM u3 [-] : -2.59E-06 BCM u10[-] : -2.061E-06
BCM d1 [0] : 0.0004426 BCM d3 [0] : -1.164E-05 BCM d10[0] : -3.961E-06
BCM d1 [+] : 0.0002008 BCM d3 [+] : -5.282E-06 BCM d10[+] : -1.797E-06
BCM d1 [-] : 0.0002007 BCM d3 [-] : -5.307E-06 BCM d10[-] : -1.805E-06
****************************
End-of-run EPICS data for Run Number 1902 at Sun Dec 18 00:53:31 EST 2011
Left Arm Top VDC Current : 1.12305
Left Arm Bottom VDC Current : -3.95508
Left Arm Top VDC voltage : 4.00781
Left Arm Bottom VDC voltage : 3.99609
-----
Right Arm Top VDC Current : -3.125
Right Arm Bottom VDC Current : 0.732422
Right Arm Top VDC voltage : 4.01758
Right Arm Bottom VDC voltage : 3.97412
-----
Left Arm Q1 momentum : 0.797693
Left Arm Q1 power supply : 600.076
Left Arm Q1 gauss meter : -0.04993
Left Arm Q2 gauss meter : 0.2608
Left Arm Q2 power supply current : 492.034
Left Arm Q2 momentum : 1.14267
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 401.856
Left Arm D1 momentum : 1.21096
Left Arm D1 NMR : 0.448274
Left Arm arm angle : -0.179
Left Arm Q3 gauss meter : -0.29424
Left Arm Q3 power supply current : 582.803
Left Arm Q3 momentum : 1.46389
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.10581
Right Arm Q1 power supply : 605.577
Right Arm Q1 gauss meter : -0.015237
Right Arm Q2 power supply current : 493.721
Right Arm Q2 momentum : 1.1325
Right Arm Q2 gauss meter : 0.2592
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 409.711
Right Arm D1 momentum : 1.21109
Right Arm D1 NMR : 0.44942
Right Arm arm angle : 12.501
Right Arm Q3 power supply current : 581.21
Right Arm Q3 momentum : 1.07739
Right Arm Q3 gauss meter : 0.2582
Right Arm Q3 power supply polarity : disabled
-----
HacL_HPE1313A:0_Ch58 : -0.296387
HacL_HPE1313A:0_Ch55 : 23.291
HacL_HPE1313A:0_Ch54 : -0.019043
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Left VDC -DISC LVL Top : 3.90723
Left VDC -DISC LVL Bottom : 3.96338
Left VDC -DISC LVL Voltage1 : 4.96777
Left VDC -DISC LVL Voltage2 : -5.05664
-----
Right Arm Collimator : 0.0505859
HacR_HPE1313A:0_Ch58 : -0.694824
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -1.02637
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.501