NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 05:15:22 on December 18, 2011
Entry number 360683
keyword=End_of_Run_21038
****************************
Run Number: 21038
End of Run Comment:
Run_type=Cosmics,target_type=empty,beam_e0=0,beam_fraster=off,beam_sraster=off,beam_current=0,rightarm_p=1.317,rightarm_theta=5.69,rightarm_sieve=out,septum_current=0,comment_text=test
PRESCALE FACTORS:ps1=0 ps2=0 ps3=0 ps4=0 ps5=0 ps6=0 ps7=0 ps8=1
EVENTS : [0]: 431875 [+]: 201452 [-]: 201438
TIME : [0]: 7.044 mins [+]: 3.307 mins [-]: 3.306 mins
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 0.20% [+]: 0.84% [-]: 0.82%
TRIGGER RATES: PRES/REAL
T1[0] :T1: 0.0/1581.4 Hz T2[0] :T2: 0.0/21.3 Hz T3[0] :T3: 0.0/801.5 Hz T4[0] :T4: 0.0/10.8 Hz T5[0] :T5: 0.0/3757.6 Hz T6[0] :T6: 0.0/2755.8 Hz T7[0] :T7: 0.0/0.0 Hz T8[0] :T8:1024.0/1024.0 Hz
T1[+] :T1: 0.0/1572.0 Hz T2[+] :T2: 0.0/21.6 Hz T3[+] :T3: 0.0/797.8 Hz T4[+] :T4: 0.0/10.8 Hz T5[+] :T5: 0.0/3742.8 Hz T6[+] :T6: 0.0/2746.5 Hz T7[+] :T7: 0.0/0.0 Hz T8[+] :T8:1024.0/1024.0 Hz
T1[-] :T1: 0.0/1571.2 Hz T2[-] :T2: 0.0/21.0 Hz T3[-] :T3: 0.0/795.5 Hz T4[-] :T4: 0.0/10.8 Hz T5[-] :T5: 0.0/3743.0 Hz T6[-] :T6: 0.0/2738.8 Hz T7[-] :T7: 0.0/0.0 Hz T8[-] :T8:1024.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] :T1: 0/668343 T2[0] :T2: 0/9006 T3[0] :T3: 0/338754 T4[0] :T4: 0/4581 T5[0] :T5: 0/1588100 T6[0] :T6: 0/1164709 T7[0] :T7: 0/0 T8[0] :T8: 432777/432777
T1[+] :T1: 0/311899 T2[+] :T2: 0/4279 T3[+] :T3: 0/158290 T4[+] :T4: 0/2150 T5[+] :T5: 0/742602 T6[+] :T6: 0/544922 T7[+] :T7: 0/0 T8[+] :T8: 203171/203171
T1[-] :T1: 0/311692 T2[-] :T2: 0/4161 T3[-] :T3: 0/157804 T4[-] :T4: 0/2137 T5[-] :T5: 0/742501 T6[-] :T6: 0/543304 T7[-] :T7: 0/0 T8[-] :T8: 203133/203133
AVERAGE CURRENT
BCM x1 : -0.2153uA BCM x3 : 57.6983uA BCM x10: 26.9460uA
Test of Helicity gates
Time diff of helicity to nonhelicity times = -1.88247 seconds
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 1E+39 ppm BCM u3 : -118.7 ppm BCM u10: -1310 ppm
BCM d1 : 1E+39 ppm BCM d3 : 1E+39 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0] : -0.0001289 BCM u3 [0] : 0.04881 BCM u10[0] : 0.02279
BCM u1 [+] : -6.051E-05 BCM u3 [+] : 0.02276 BCM u10[+] : 0.01061
BCM u1 [-] : -6.05E-05 BCM u3 [-] : 0.02276 BCM u10[-] : 0.01064
BCM d1 [0] : -5.308E-05 BCM d3 [0] : -3.526E-05 BCM d10[0] : -1.199E-05
BCM d1 [+] : -2.492E-05 BCM d3 [+] : -1.655E-05 BCM d10[+] : -5.631E-06
BCM d1 [-] : -2.491E-05 BCM d3 [-] : -1.655E-05 BCM d10[-] : -5.63E-06
****************************
End-of-run EPICS data for Run Number 21038 at Sun Dec 18 05:15:20 EST 2011
Left Arm Top VDC Current : 5.12695
Left Arm Bottom VDC Current : -26.7578
Left Arm Top VDC voltage : 4.00732
Left Arm Bottom VDC voltage : 4
-----
Right Arm Top VDC Current : 1.12305
Right Arm Bottom VDC Current : -0.488281
Right Arm Top VDC voltage : 4.0166
Right Arm Bottom VDC voltage : 3.97168
-----
Left Arm Q1 momentum : 0.797622
Left Arm Q1 power supply : 600.13
Left Arm Q1 gauss meter : -0.04991
Left Arm Q2 gauss meter : 0.2608
Left Arm Q2 power supply current : 492.036
Left Arm Q2 momentum : 1.14267
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 401.86
Left Arm D1 momentum : 1.211
Left Arm D1 NMR : 0.448288
Left Arm arm angle : -0.179
Left Arm Q3 gauss meter : -0.29422
Left Arm Q3 power supply current : 582.809
Left Arm Q3 momentum : 1.46391
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.10591
Right Arm Q1 power supply : 605.524
Right Arm Q1 gauss meter : -0.015226
Right Arm Q2 power supply current : 493.724
Right Arm Q2 momentum : 1.1325
Right Arm Q2 gauss meter : 0.2592
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 414.166
Right Arm D1 momentum : 1.211
Right Arm D1 NMR : 0.449389
Right Arm arm angle : 12.501
Right Arm Q3 power supply current : 581.214
Right Arm Q3 momentum : 1.07739
Right Arm Q3 gauss meter : 0.2582
Right Arm Q3 power supply polarity : disabled
-----
HacL_HPE1313A:0_Ch58 : -0.297852
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.0209961
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Left VDC -DISC LVL Top : 3.90527
Left VDC -DISC LVL Bottom : 3.96094
Left VDC -DISC LVL Voltage1 : 4.96973
Left VDC -DISC LVL Voltage2 : -5.06055
-----
Right Arm Collimator : 0.0509277
HacR_HPE1313A:0_Ch58 : -0.697266
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -1.02539
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.501