Log entry time 22:35:00 on December 19, 2011
Entry number 360950
keyword=Moller polarimeter results
Moller polarimeter test results on December 19, 12:00-22:30
- Crew: Roman, Sasha
- Wien filter angle is 0.0°
- The raster was OFF.
- The half wave plate was OUT.
- Beam was straight.
- Moller detector HV adjustment for 3 passes energy was done.
- 12:00 - 14:20 Beam restoration, Moller settings, Moller FSD problem
- Moller FSD problem was fixed(see elog 1655865)
- 14:20 - 16:48 No beam
- 16:48 - 17:40 Runs 15040-15046 Moller detector HV tuning
(Helicity 30Hz, Beam charge asymmetry is huge -0.04206)
- Runs 15048-15049 Helicity 960Hz
- Runs 15050-15063: Moller Quad1 scan.
- Runs 15064-15072: Moller Quad3 scan.
- Run 15075 (20:08) Beam charge asymmetry is back to normal (0.00071).
- Runs 15073-15081: Target 4 test.
- Runs 15082-15 : Target 2 test.
- Beam polarization ~62%.