NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 11:33:56 on December 20, 2011
Entry number 361098
keyword=End_of_Run_21117
****************************
Run Number: 21117
End of Run Comment:
Run_type=Calibration,target_type=Carbon,beam_e0=1.72,beam_fraster=off,beam_sraster=off,beam_current=1,rightarm_p=1.683,rightarm_theta=5.69,rightarm_sieve=out,septum_current=415,comment_text=Alexandre's BCM test, slow raster ON
PRESCALE FACTORS:ps1=1 ps2=1 ps3=0 ps4=0 ps5=0 ps6=0 ps7=0 ps8=0
EVENTS : [0]: 81969 [+]: 38180 [-]: 38295
TIME : [0]: 5.606 mins [+]: 2.640 mins [-]: 2.639 mins
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 3.65% [+]: 3.68% [-]: 3.70%
TRIGGER RATES: PRES/REAL
T1[0] :T1:248.7/248.7 Hz T2[0] :T2: 4.2/4.2 Hz T3[0] :T3: 0.0/196.7 Hz T4[0] :T4: 0.0/5.6 Hz T5[0] :T5: 0.0/1638.2 Hz T6[0] :T6: 0.0/953.7 Hz T7[0] :T7: 0.0/0.0 Hz T8[0] :T8: 0.0/1024.0 Hz
T1[+] :T1:246.1/246.1 Hz T2[+] :T2: 4.2/4.2 Hz T3[+] :T3: 0.0/196.9 Hz T4[+] :T4: 0.0/5.6 Hz T5[+] :T5: 0.0/1636.2 Hz T6[+] :T6: 0.0/951.8 Hz T7[+] :T7: 0.0/0.0 Hz T8[+] :T8: 0.0/1024.0 Hz
T1[-] :T1:247.1/247.1 Hz T2[-] :T2: 4.1/4.1 Hz T3[-] :T3: 0.0/193.5 Hz T4[-] :T4: 0.0/5.6 Hz T5[-] :T5: 0.0/1633.6 Hz T6[-] :T6: 0.0/949.5 Hz T7[-] :T7: 0.0/0.0 Hz T8[-] :T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] :T1: 83671/83671 T2[0] :T2: 1412/1412 T3[0] :T3: 0/66154 T4[0] :T4: 0/1876 T5[0] :T5: 0/551029 T6[0] :T6: 0/320812 T7[0] :T7: 0/0 T8[0] :T8: 0/344443
T1[+] :T1: 38980/38980 T2[+] :T2: 663/663 T3[+] :T3: 0/31186 T4[+] :T4: 0/894 T5[+] :T5: 0/259140 T6[+] :T6: 0/150748 T7[+] :T7: 0/0 T8[+] :T8: 0/162178
T1[-] :T1: 39117/39117 T2[-] :T2: 655/655 T3[-] :T3: 0/30634 T4[-] :T4: 0/885 T5[-] :T5: 0/258643 T6[-] :T6: 0/150328 T7[-] :T7: 0/0 T8[-] :T8: 0/162129
AVERAGE CURRENT
BCM x1 : 45.9211uA
Test of Helicity gates
Time diff of helicity to nonhelicity times = -2.47368 seconds
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -5483 ppm
BCM d1 : -364.5 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0] : 0.01539
BCM u1 [+] : 0.007149
BCM u1 [-] : 0.007226
BCM d1 [0] : 0.01551
BCM d1 [+] : 0.007237
BCM d1 [-] : 0.00724
****************************
End-of-run EPICS data for Run Number 21117 at Tue Dec 20 11:33:52 EST 2011
Left Arm Top VDC Current : 0.341797
Left Arm Bottom VDC Current : 32.9102
Left Arm Top VDC voltage : 4.01074
Left Arm Bottom VDC voltage : 3.99902
-----
Right Arm Top VDC Current : 0.341797
Right Arm Bottom VDC Current : 0.78125
Right Arm Top VDC voltage : 4.01807
Right Arm Bottom VDC voltage : 3.9751
-----
Left Arm Q1 momentum : 1.10905
Left Arm Q1 power supply : 834.371
Left Arm Q1 gauss meter : -0.06936
Left Arm Q2 gauss meter : 0.3626
Left Arm Q2 power supply current : 684.835
Left Arm Q2 momentum : 1.59042
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 563.287
Left Arm D1 momentum : 1.68302
Left Arm D1 NMR : 0.622848
Left Arm arm angle : -0.179
Left Arm Q3 gauss meter : -0.40873
Left Arm Q3 power supply current : 809.623
Left Arm Q3 momentum : 2.03362
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.53632
Right Arm Q1 power supply : 841.26
Right Arm Q1 gauss meter : -0.021074
Right Arm Q2 power supply current : 686.199
Right Arm Q2 momentum : 1.574
Right Arm Q2 gauss meter : 0.3607
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 572.227
Right Arm D1 momentum : 1.67979
Right Arm D1 NMR : 0.623349
Right Arm arm angle : 12.501
Right Arm Q3 power supply current : 807.656
Right Arm Q3 momentum : 1.49715
Right Arm Q3 gauss meter : 0.3588
Right Arm Q3 power supply polarity : disabled
-----
HacL_HPE1313A:0_Ch58 : -0.297852
HacL_HPE1313A:0_Ch55 : 23.291
HacL_HPE1313A:0_Ch54 : -0.0209961
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Left VDC -DISC LVL Top : 3.90771
Left VDC -DISC LVL Bottom : 3.96484
Left VDC -DISC LVL Voltage1 : 4.97021
Left VDC -DISC LVL Voltage2 : -5.06055
-----
Right Arm Collimator : 0.061377
HacR_HPE1313A:0_Ch58 : -0.696777
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -1.02197
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.501
Left Septum Magnet Current : 470.366
Right Septum Magnet Current : 469.956
-----