• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 05:17:44 on December 21, 2011

    Entry number 361342

    keyword=End_of_Run_2069
    ****************************
     Run Number: 2069
     End of Run Comment:
    Run_type=Commission,target_type=Carbon,beam_e0=1.72,beam_fraster=off,beam_sraster=off,beam_current=1,leftarm_p=0.526,leftarm_theta=5.69,leftarm_sieve=out,septum_current=149,comment_text=carbon inelastic spectrum
     
    
    PRESCALE FACTORS:ps1=0   ps2=0   ps3=1   ps4=1   ps5=0   ps6=0   ps7=0   ps8=0   
    
    EVENTS   : [0]: 1060838      [+]: 494593       [-]: 494727       
    TIME     : [0]: 6.432 mins  [+]: 3.027 mins  [-]: 3.027 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  11.48%      [+]:  12.28%      [-]:  12.33%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :T1: 0.0/19540.4 Hz   T2[0] :T2: 0.0/87.9 Hz   T3[0] :T3:3082.6/3082.6 Hz   T4[0] :T4:23.0/23.0 Hz   T5[0] :T5: 0.0/0.0  Hz   T6[0] :T6: 0.0/7293.9 Hz   T7[0] :T7: 0.0/103756.5 Hz   T8[0] :T8: 0.0/1024.0 Hz   
    T1[+] :T1: 0.0/19542.7 Hz   T2[+] :T2: 0.0/88.0 Hz   T3[+] :T3:3081.6/3081.6 Hz   T4[+] :T4:22.7/22.7 Hz   T5[+] :T5: 0.0/0.0  Hz   T6[+] :T6: 0.0/7296.7 Hz   T7[+] :T7: 0.0/103757.4 Hz   T8[+] :T8: 0.0/1024.0 Hz   
    T1[-] :T1: 0.0/19529.9 Hz   T2[-] :T2: 0.0/87.7 Hz   T3[-] :T3:3083.4/3083.4 Hz   T4[-] :T4:23.4/23.4 Hz   T5[-] :T5: 0.0/0.0  Hz   T6[-] :T6: 0.0/7294.5 Hz   T7[-] :T7: 0.0/103754.6 Hz   T8[-] :T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :T1:      0/7541203  T2[0] :T2:      0/33913    T3[0] :T3:1189646/1189646  T4[0] :T4:   8879/8879     T5[0] :T5:      0/0        T6[0] :T6:      0/2814913  T7[0] :T7:      0/40042626  T8[0] :T8:      0/395191   
    T1[+] :T1:      0/3549769  T2[+] :T2:      0/15980    T3[+] :T3: 559751/559751   T4[+] :T4:   4122/4122     T5[+] :T5:      0/0        T6[+] :T6:      0/1325379  T7[+] :T7:      0/18846655  T8[+] :T8:      0/186001   
    T1[-] :T1:      0/3547575  T2[-] :T2:      0/15931    T3[-] :T3: 560093/560093   T4[-] :T4:   4258/4258     T5[-] :T5:      0/0        T6[-] :T6:      0/1325042  T7[-] :T7:      0/18846871  T8[-] :T8:      0/186008   
    
    AVERAGE CURRENT
    BCM 1 : 1.1069 uA  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -2.75530 seconds
    
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    88.86 ppm     
    BCM d1 :    226.3 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0] : 0.0004778      
    BCM u1 [+] : 0.0002229      
    BCM u1 [-] : 0.0002229      
    
    BCM d1 [0] : 0.0003765      
    BCM d1 [+] : 0.0001772      
    BCM d1 [-] : 0.0001772      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2069 at Wed Dec 21 05:17:40 EST 2011
    
    Left Arm Top VDC Current : 4.83398
    Left Arm Bottom VDC Current : -19.4336
    Left Arm Top VDC voltage : 4.00488
    Left Arm Bottom VDC voltage : 4
    -----
    Right Arm Top VDC Current : -0.0488281
    Right Arm Bottom VDC Current : -3.75977
    Right Arm Top VDC voltage : 4.01562
    Right Arm Bottom VDC voltage : 3.9707
    -----
    Left Arm Q1 momentum : 0.343733
    Left Arm Q1 power supply : 260.784
    Left Arm Q1 gauss meter : -0.02166
    Left Arm Q2 gauss meter : 0.11304
    Left Arm Q2 power supply current : 212.207
    Left Arm Q2 momentum : 0.492816
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 172.606
    Left Arm D1 momentum : 0.526004
    Left Arm D1 NMR : 0.194861
    Left Arm arm angle : -0.179
    Left Arm Q3 gauss meter : -0.128446
    Left Arm Q3 power supply current : 253.611
    Left Arm Q3 momentum : 0.637022
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 0.481025
    Right Arm Q1 power supply : 263.401
    Right Arm Q1 gauss meter : -0.00669
    Right Arm Q2 power supply current : 214.353
    Right Arm Q2 momentum : 0.491682
    Right Arm Q2 gauss meter : 0.11297
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 159.556
    Right Arm D1 momentum : 0.52602
    Right Arm D1 NMR : 0.195199
    Right Arm arm angle : 12.501
    Right Arm Q3 power supply current : 252.551
    Right Arm Q3 momentum : 0.468152
    Right Arm Q3 gauss meter : 0.11248
    Right Arm Q3 power supply polarity : disabled
    -----
    HacL_HPE1313A:0_Ch58 : -0.299316
    HacL_HPE1313A:0_Ch55 : 23.4375
    HacL_HPE1313A:0_Ch54 : -0.0185547
    Left Arm Angle Vernier : 0
    Left Arm Scattering Angle : -0.179
    Left VDC -DISC LVL Top : 3.90723
    Left VDC -DISC LVL Bottom : 3.9624
    Left VDC -DISC LVL Voltage1 : 4.96826
    Left VDC -DISC LVL Voltage2 : -5.06152
    -----
    Right Arm Collimator : 0.0381348
    HacR_HPE1313A:0_Ch58 : -0.697754
    HacR_HPE1313A:0_Ch55 : 22.3633
    HacR_HPE1313A:0_Ch54 : -1.02393
    Right Arm Angle Floor Angle : 12.5
    Right Arm Angle Vernier : -34
    Right Arm Scattering Angle : 12.501
    Left Septum Magnet Current : 148.601
    Right Septum Magnet Current : 148.972
    -----