NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 01:21:42 on December 22, 2011
Entry number 361588
keyword=End_of_Run_2127
****************************
Run Number: 2127
End of Run Comment:
Run_type=Commission,target_type=Carbon,beam_e0=1.72,beam_fraster=off,beam_sraster=off,beam_current=0.157,leftarm_p=1.700,leftarm_theta=5.69,leftarm_sieve=out,septum_current=475,comment_text=BCM low current test 157nA
PRESCALE FACTORS:ps1=0 ps2=0 ps3=1 ps4=0 ps5=0 ps6=0 ps7=0 ps8=0
EVENTS : [0]: 608117 [+]: 283204 [-]: 283884
TIME : [0]: 4.272 mins [+]: 2.011 mins [-]: 2.011 mins
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 9.75% [+]: 10.72% [-]: 10.62%
TRIGGER RATES: PRES/REAL
T1[0] :T1: 0.0/5921.5 Hz T2[0] :T2: 0.0/40.6 Hz T3[0] :T3:2629.3/2629.3 Hz T4[0] :T4: 0.0/18.6 Hz T5[0] :T5: 0.0/0.0 Hz T6[0] :T6: 0.0/6748.2 Hz T7[0] :T7: 0.0/103898.9 Hz T8[0] :T8: 0.0/1024.0 Hz
T1[+] :T1: 0.0/5930.7 Hz T2[+] :T2: 0.0/40.8 Hz T3[+] :T3:2629.3/2629.3 Hz T4[+] :T4: 0.0/18.5 Hz T5[+] :T5: 0.0/0.0 Hz T6[+] :T6: 0.0/6752.7 Hz T7[+] :T7: 0.0/103905.1 Hz T8[+] :T8: 0.0/1024.0 Hz
T1[-] :T1: 0.0/5919.6 Hz T2[-] :T2: 0.0/40.7 Hz T3[-] :T3:2632.4/2632.4 Hz T4[-] :T4: 0.0/18.6 Hz T5[-] :T5: 0.0/0.0 Hz T6[-] :T6: 0.0/6745.1 Hz T7[-] :T7: 0.0/103898.0 Hz T8[-] :T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] :T1: 0/1517631 T2[0] :T2: 0/10415 T3[0] :T3: 673862/673862 T4[0] :T4: 0/4779 T5[0] :T5: 0/0 T6[0] :T6: 0/1729494 T7[0] :T7: 0/26628348 T8[0] :T8: 0/262442
T1[+] :T1: 0/715580 T2[+] :T2: 0/4925 T3[+] :T3: 317245/317245 T4[+] :T4: 0/2238 T5[+] :T5: 0/0 T6[+] :T6: 0/814757 T7[+] :T7: 0/12536803 T8[+] :T8: 0/123552
T1[-] :T1: 0/714285 T2[-] :T2: 0/4913 T3[-] :T3: 317639/317639 T4[-] :T4: 0/2250 T5[-] :T5: 0/0 T6[-] :T6: 0/813896 T7[-] :T7: 0/12536855 T8[-] :T8: 0/123561
AVERAGE CURRENT
BCM 1 : 0.1365 uA
Test of Helicity gates
Time diff of helicity to nonhelicity times = -1.89863 seconds
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 147.5 ppm
BCM d1 : 116.3 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0] : 3E-05
BCM u1 [+] : 1.413E-05
BCM u1 [-] : 1.412E-05
BCM d1 [0] : 3.999E-05
BCM d1 [+] : 1.883E-05
BCM d1 [-] : 1.883E-05
****************************
End-of-run EPICS data for Run Number 2127 at Thu Dec 22 01:21:39 EST 2011
Left Arm Top VDC Current : 4.63867
Left Arm Bottom VDC Current : 17.9199
Left Arm Top VDC voltage : 4.00586
Left Arm Bottom VDC voltage : 3.99805
-----
Right Arm Top VDC Current : -0.634766
Right Arm Bottom VDC Current : -3.4668
Right Arm Top VDC voltage : 4.01514
Right Arm Bottom VDC voltage : 3.97119
-----
Left Arm Q1 momentum : 1.12026
Left Arm Q1 power supply : 842.809
Left Arm Q1 gauss meter : -0.07003
Left Arm Q2 gauss meter : 0.3664
Left Arm Q2 power supply current : 691.931
Left Arm Q2 momentum : 1.6069
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 569.407
Left Arm D1 momentum : 1.69999
Left Arm D1 NMR : 0.629123
Left Arm arm angle : -0.179
Left Arm Q3 gauss meter : -0.41275
Left Arm Q3 power supply current : 817.788
Left Arm Q3 momentum : 2.05413
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.12362
Right Arm Q1 power supply : 844.892
Right Arm Q1 gauss meter : -0.02115
Right Arm Q2 power supply current : 693.27
Right Arm Q2 momentum : 1.61088
Right Arm Q2 gauss meter : 0.3643
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 495.589
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.360519
Right Arm arm angle : 0.197
Right Arm Q3 power supply current : 815.807
Right Arm Q3 momentum : 2.05024
Right Arm Q3 gauss meter : 0.3625
Right Arm Q3 power supply polarity : disabled
-----
HacL_HPE1313A:0_Ch58 : -0.299316
HacL_HPE1313A:0_Ch55 : 23.291
HacL_HPE1313A:0_Ch54 : -0.0195312
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Left VDC -DISC LVL Top : 3.90527
Left VDC -DISC LVL Bottom : 3.96094
Left VDC -DISC LVL Voltage1 : 4.96777
Left VDC -DISC LVL Voltage2 : -5.06348
-----
Right Arm Collimator : 0.0598633
HacR_HPE1313A:0_Ch58 : -0.698242
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -1.02393
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
Left Septum Magnet Current : 475.334
Right Septum Magnet Current : 474.939
-----