• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 17:07:21 on January 9, 2012

    Entry number 361895

    keyword=Start_Run_2229,Run_type=Cosmics,target_type=empty,comment_text=Rate test
    Beginning-of-run EPICS data for Run Number 2229 at Mon Jan 9 17:07:16 EST 2012
    
    
    
    Run_type=Cosmics
    target_type=empty
    comment_text=Rate test
    
    
    ps1=0,ps2=0,ps3=0,ps4=0,ps5=0,ps6=0,ps7=1,ps8=0
    
    
    
    
    Left Arm Q1 momentum : 0.00257381
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0001445
    Left Arm Q2 power supply current : -0.000164727
    Left Arm Q2 momentum : -3.82552e-07
    Left Arm Q2 gauss meter : 0.001129
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 0.0993165
    Left Arm D1 momentum : 0.00332127
    Left Arm D1 NMR : 0.173879
    Left Arm Q3 power supply current : -0.000334777
    Left Arm Q3 momentum : -8.40899e-07
    Left Arm Q3 gauss meter : -0.00023255
    Left Arm Q3 power supply polarity : enabled
    Left Arm B Field Hall Probe (D-G) : -0.0012044
    -----
    Right Arm Q1 momentum : 0.00653234
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.0001432
    Right Arm Q2 power supply current : 19.8145
    Right Arm Q2 momentum : 0.00103377
    Right Arm Q2 gauss meter : 0.0002141
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : -0.000194155
    Right Arm D1 momentum : 0.00415066
    Right Arm D1 NMR : 0.360579
    Right Arm Q3 power supply current : -4.48357e-05
    Right Arm Q3 momentum : -1.97187e-07
    Right Arm Q3 gauss meter : 0.010823
    Right Arm Q3 power supply polarity : enabled
    Right Arm B Field Hall Probe (D-G) : -0.0015048
    -----
    Left Arm Top VDC Current : 2.14844
    Left Arm Bottom VDC Current : -25.9277
    Left Arm Top VDC voltage : 4.00732
    Left Arm Bottom VDC voltage : 4
    -----
    Right Arm Top VDC Current : -1.5625
    Right Arm Bottom VDC Current : -1.66016
    Right Arm Top VDC voltage : 4.01318
    Right Arm Bottom VDC voltage : 3.97119
    -----
    Hall A current reading : 0
    BCM Pre Gain 1 A : 28
    BCM Pre Gain 2 A : 28
    Mag Div by 2^n A : 514
    BCM Pre Gain 1 B : 28
    BCM Pre Gain 2 B : 28
    Mag Div by 2^n B : 514
    -----
    HacL_HPE1313A:0_Ch58 : -0.296875
    HacL_HPE1313A:0_Ch55 : 23.3398
    HacL_HPE1313A:0_Ch54 : -0.012207
    Left Arm Angle Floor Angle : 0
    Left Arm Angle Vernier : 0
    Left Arm Scattering Angle : -0.179
    -----
    Right Arm D1 momentum : 0.00410105
    Right Arm arm angle : 0.197
    -----
    Left VDC -DISC LVL Top : 3.90771
    Left VDC -DISC LVL Bottom : 3.96484
    Left VDC -DISC LVL Voltage1 : 4.96777
    Left VDC -DISC LVL Voltage2 : -5.05127
    Left VDC -DISC LVL Top Set : 4
    Left VDC -DISC LVL Bottom Set : 4
    -----
    HacR_HPE1313A:0_Ch58 : -0.695312
    HacR_HPE1313A:0_Ch55 : 22.3633
    HacR_HPE1313A:0_Ch54 : -1.02002
    Right Arm Angle Floor Angle : 0
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 0.197
    -----
    IPM1C12.XPOS : 0
    IPM1C12.YPOS : 0
    IPM1H05A.XPOS : 0
    IPM1H05A.YPOS : 0
    IPM1H05B.XPOS : 0
    IPM1H05B.YPOS : 0
    Survey X offset bpmA : 0
    Survey Y offset bpmA : 0
    Survey X offset bpmB : 0
    Survey Y offset bpmB : 0
    -----
    Wien angle (Vertical) : 89.9999
    Wien Vertical BDL (Gcm) : 2626.6
    Wien HV Polarity : POSITIVE
    Wien electrode Voltage : 0
    Wien angle (Solenoids) : -92.0371
    Wien BDL (First Solenoid) (Gcm) : -1021.5
    Wien BDL (Second Solenoid) (Gcm) : -1021.5
    Wien angle (Horizontal) : -60.5008
    Wien BDL (Gcm) : -1747.1
    Wien HV Polarity (Horizontal) : NEGATIVE
    Wien electrode Voltage (Horizontal) : 0
    Laser attenuation Hall A : 140
    Laser power Hall A : 0
    Half-wave plate (off=out) : OUT
    rotating waveplate : 100
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Delay Set : 8 windows
    Helicity Pattern Set : Quartet
    Helicity Clock Set : Free Clock
    Helicity Settle Read : 70
    Helicity Stable Read : 971.65
    Helicity Delay Read : 8 windows
    Helicity Pattern : Quartet
    Helicity Clock Read : Free Clock
    Helicity Frequency : 960.015
    Right septum current : 0
    Left septum current : 0.0210483
    Target In : enabled
    Target Out : enabled
    Helium Pressure : enabled