• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 14:21:38 on March 3, 2012

    Entry number 363045

    keyword=End_of_Run_2651
    ****************************
     Run Number: 2651
     End of Run Comment:
    Run_type=Commission,target_type=empty,comment_text=bpm check with 100 na current
     
    
    bad HRS arm: UNKNOWN (should be LEFT or RIGHT)
    
    ****************************
    End-of-run EPICS data for Run Number 2651 at Sat Mar 3 14:21:35 EST 2012
    
    

    Target Info

    Target number in beam : 0 Target encoder position : 0 uWave Frequency (Ghz) : -999 RF Frequency (Mhz) : -999 Magnetic Field (T) : -999 Magnet Current : -999 VPT 3He (K) : -999 VPT 4He (K) : 1.29987 NMR Area : -999 Polarization : -999

    General Run Info

    Beam energy (MeV) : 2252.94 Beam Current : 179.76 Left arm angle : 12.502 Left arm momentum : 2.22671 Right arm angle : 12.5005 Right arm momentum : 0 Left septum current : 726.229 Right septum current : 720.909

    Misc Epics Info

    ----- Left Arm Q1 momentum : 2.22731 Left Arm Q1 power supply : 1137.83 Left Arm Q1 gauss meter : -0.09464 Left Arm Q2 gauss meter : 0.4802 Left Arm Q2 power supply current : 907.659 Left Arm Q2 momentum : 2.22719 Left Arm Q2 power supply polarity : disabled Left Arm D1 power supply current : 758.11 Left Arm D1 momentum : 2.22671 Left Arm D1 NMR : 0.823898 Left Arm Q3 gauss meter : -0.54218 Left Arm Q3 power supply current : 1074.62 Left Arm Q3 momentum : 2.22731 Left Arm Q3 power supply polarity : disabled ----- Right Arm Q1 momentum : 2.22717 Right Arm Q1 power supply : 1130.78 Right Arm Q1 gauss meter : -0.02819 Right Arm Q2 power supply current : 909.951 Right Arm Q2 momentum : 2.22719 Right Arm Q2 gauss meter : 0.479 Right Arm Q2 power supply polarity : enabled Right Arm D1 power supply current : 783.693 Right Arm D1 momentum : 0 Right Arm D1 NMR : 1.12417 Right Arm Q3 power supply current : 1072.6 Right Arm Q3 momentum : 2.22731 Right Arm Q3 gauss meter : 0.4754 Right Arm Q3 power supply polarity : disabled ----- Left Arm Angle Floor Angle : 12.5 Left Arm Angle Vernier : 31.4 Left Arm Scattering Angle : 12.502 ----- Right Arm Angle Floor Angle : 12.5 Right Arm Angle Vernier : -34.1 Right Arm Scattering Angle : 12.5005 ----- Wien angle (Vertical) : 89.9999 Wien Vertical BDL (Gcm) : 2649.6 Wien HV Polarity : POSITIVE Wien electrode Voltage : 0 Wien angle (Solenoids) : 88.7125 Wien BDL (First Solenoid) (Gcm) : 1239.7 Wien BDL (Second Solenoid) (Gcm) : 729.5 Wien angle (Horizontal) : -60.8504 Wien BDL (Gcm) : -1753 Wien HV Polarity (Horizontal) : NEGATIVE Wien electrode Voltage (Horizontal) : 0 Laser attenuation Hall A : 110 Laser power Hall A : 0 Half-wave plate (off=out) : IN rotating waveplate : 329 Beam Half-wave plate (off=out) : IN ----- Helicity Delay Set : 8 windows Helicity Pattern Set : Quartet Helicity Clock Set : Free Clock Helicity Settle Read : 70 Helicity Stable Read : 971.65 Helicity Delay Read : 8 windows Helicity Pattern : Quartet Helicity Clock Read : Free Clock Helicity Frequency : 960.015 Left Septum Magnet Current : 726.229 Right Septum Magnet Current : 720.893 -----