NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 18:31:07 on March 8, 2012
Entry number 364714
keyword=End_of_Run_22028
****************************
Run Number: 22028
End of Run Comment:
Run_type=Optics,target_type=Carbon thin,comment_text=C12(40mil) no LHe, fast & slow rasters OFF, Sieve IN, position
PRESCALE FACTORS:can't read "psfacline": no such variable
while executing
"$w insert end "$psfacline..."
(procedure "halla_scaler_process" line 396)
invoked from within
"halla_scaler_process .mid.tex scalerinfo "
****************************
End-of-run EPICS data for Run Number 22028 at Thu Mar 8 18:30:59 EST 2012
Target Info
Target number in beam : 0
Target encoder position : haptPT_Encoder --- Invalid channel name
uWave Frequency (Ghz) : -999
RF Frequency (Mhz) : -999
Magnetic Field (T) : -999
Magnet Current : 60.913
VPT 3He (K) : 0
VPT 4He (K) : 1.2929
NMR Area : -999
Polarization : -999
General Run Info
Beam energy (MeV) : 2253.21
Beam Current : 180.75
Left arm angle : 12.502
Left arm momentum : 2.25094
Right arm angle : 12.5005
Right arm momentum : 2.25097
Left septum current : 725.345
Right septum current : 725.315
Misc Epics Info
-----
Left Arm Q1 momentum : 2.25125
Left Arm Q1 power supply : 1150
Left Arm Q1 gauss meter : -0.09564
Left Arm Q2 gauss meter : 0.4854
Left Arm Q2 power supply current : 917.507
Left Arm Q2 momentum : 2.25135
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 767.294
Left Arm D1 momentum : 2.25094
Left Arm D1 NMR : 0.832868
Left Arm Q3 gauss meter : -0.548
Left Arm Q3 power supply current : 1086.12
Left Arm Q3 momentum : 2.25114
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 2.25115
Right Arm Q1 power supply : 1142.95
Right Arm Q1 gauss meter : -0.02854
Right Arm Q2 power supply current : 919.801
Right Arm Q2 momentum : 2.2513
Right Arm Q2 gauss meter : 0.4841
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 788.247
Right Arm D1 momentum : 2.25097
Right Arm D1 NMR : 0.835308
Right Arm Q3 power supply current : 1084.02
Right Arm Q3 momentum : 2.25103
Right Arm Q3 gauss meter : 0.4805
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31.4
Left Arm Scattering Angle : 12.502
-----
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.1
Right Arm Scattering Angle : 12.5005
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 88.7125
Wien BDL (First Solenoid) (Gcm) : 1239.7
Wien BDL (Second Solenoid) (Gcm) : 729.5
Wien angle (Horizontal) : -59.6266
Wien BDL (Gcm) : -1721.1
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 110
Laser power Hall A : 0
Half-wave plate (off=out) : IN
rotating waveplate : 329
Beam Half-wave plate (off=out) : IN
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 725.345
Right Septum Magnet Current : 725.315
-----