NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 10:14:14 on March 31, 2012
Entry number 368596
keyword=End_of_Run_3532
****************************
Run Number: 3532
End of Run Comment:
Run_type=Production,target_type=NH3 top,comment_text=momentum 1.550
PRESCALE FACTORS:can't read "psfacline": no such variable
while executing
"$w insert end "$psfacline..."
(procedure "halla_scaler_process" line 195)
invoked from within
"halla_scaler_process .mid.tex scalerinfo "
****************************
End-of-run EPICS data for Run Number 3532 at Sat Mar 31 10:14:09 EDT 2012
Target Info
Target number in beam : 1
Target encoder position : 49092
uWave Frequency (Ghz) : 0
RF Frequency (Mhz) : 106.5
Magnetic Field (T) : 2.49865
Magnet Current : 60.882
VPT 3He (K) : 1.15157
VPT 4He (K) : 1.13765
NMR Area : 7.57912
Polarization : -26.4012
General Run Info
Beam energy (MeV) : 2253.59
Beam Current : 0.073547
Beam Current (Hall C) : 179.82
Left arm angle : -0.179
Left arm momentum : 1.54998
Right arm angle : 0.197
Right arm momentum : 1.55003
Left septum current : 487.542
Right septum current : 539.46
Misc Epics Info
-----
Left Arm Q1 momentum : 1.55007
Left Arm Q1 power supply : 791.859
Left Arm Q1 gauss meter : -0.06591
Left Arm Q2 gauss meter : 0.3344
Left Arm Q2 power supply current : 631.503
Left Arm Q2 momentum : 1.54956
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 516.547
Left Arm D1 momentum : 1.54998
Left Arm D1 NMR : 0.573646
Left Arm Q3 gauss meter : -0.37741
Left Arm Q3 power supply current : 747.893
Left Arm Q3 momentum : 1.55012
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.54996
Right Arm Q1 power supply : 786.946
Right Arm Q1 gauss meter : -0.019717
Right Arm Q2 power supply current : 633.213
Right Arm Q2 momentum : 1.54985
Right Arm Q2 gauss meter : 0.3335
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 531.559
Right Arm D1 momentum : 1.55003
Right Arm D1 NMR : 0.575199
Right Arm Q3 power supply current : 746.415
Right Arm Q3 momentum : 1.54998
Right Arm Q3 gauss meter : 0.3309
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 88.7125
Wien BDL (First Solenoid) (Gcm) : 1239.7
Wien BDL (Second Solenoid) (Gcm) : 729.5
Wien angle (Horizontal) : -59.6266
Wien BDL (Gcm) : -1721.1
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 139
Laser power Hall A : 0
Rotating waveplate : 329
Fake Half-Wave Plate (8960=OUT) : 8960
Beam Half-wave plate (off=out) : OUT
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 487.563
Right Septum Magnet Current : 539.444
-----