Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 17:08:43 on April 4, 2012
Entry number 369955
keyword=End_of_Run_3698
****************************
Run Number: 3698
End of Run Comment:
junk
PRESCALE FACTORS:can't read "psfacline": no such variable
while executing
"$w insert end "$psfacline..."
(procedure "halla_scaler_process" line 195)
invoked from within
"halla_scaler_process .mid.tex scalerinfo "
****************************
End-of-run EPICS data for Run Number 3698 at Wed Apr 4 17:08:38 EDT 2012
Target Info
Target number in beam : 1
Target encoder position : 42
uWave Frequency (Ghz) : 0
RF Frequency (Mhz) : 106.5
Magnetic Field (T) : 2.49865
Magnet Current : 60.882
VPT 3He (K) : 0.942127
VPT 4He (K) : 0.971738
NMR Area : 10
Polarization : 32.9902
General Run Info
Beam energy (MeV) : 2252.94
Beam Current : -0.000163879
Beam Current (Hall C) : 0
Left arm angle : -0.179
Left arm momentum : 2.07198
Right arm angle : 0.197
Right arm momentum : 2.07201
Left septum current : 660.98
Right septum current : 735.088
Misc Epics Info
-----
Left Arm Q1 momentum : 2.07185
Left Arm Q1 power supply : 1058.41
Left Arm Q1 gauss meter : -0.08807
Left Arm Q2 gauss meter : 0.4467
Left Arm Q2 power supply current : 844.209
Left Arm Q2 momentum : 2.0715
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 701.526
Left Arm D1 momentum : 2.07198
Left Arm D1 NMR : 0.766687
Left Arm Q3 gauss meter : -0.50457
Left Arm Q3 power supply current : 999.779
Left Arm Q3 momentum : 2.07219
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 2.07201
Right Arm Q1 power supply : 1052
Right Arm Q1 gauss meter : -0.02624
Right Arm Q2 power supply current : 846.436
Right Arm Q2 momentum : 2.07173
Right Arm Q2 gauss meter : 0.4462
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 720.956
Right Arm D1 momentum : 2.07201
Right Arm D1 NMR : 0.768898
Right Arm Q3 power supply current : 998.082
Right Arm Q3 momentum : 2.07258
Right Arm Q3 gauss meter : 0.4423
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 88.7125
Wien BDL (First Solenoid) (Gcm) : 1239.7
Wien BDL (Second Solenoid) (Gcm) : 729.5
Wien angle (Horizontal) : -59.6266
Wien BDL (Gcm) : -1721.1
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 135
Laser power Hall A : 0
Rotating waveplate : 329
Fake Half-Wave Plate (8960=OUT) : 8960
Beam Half-wave plate (off=out) : IN
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 660.895
Right Septum Magnet Current : 735.088
-----